10kv/12kv Transformer Capacitance Tan Delta Test Set Transformer Capacitance Dissipation Factor Tester 1 Transformer Testing Machine

10kv/12kv Transformer Capacitance Tan Delta Test Set Transformer Capacitance Dissipation Factor Tester 1 Transformer Testing Machine

FTD-6000 Transformer Tan Delta and Capacitance Tester is a new generation test instrument for power industry, which fully automatic on-site measuring dielectric loss (tgδ) and the capacitance (Cx) of electric equipment.
Send Inquiry

Product Introduction

We have a complete enterprise structure for product development, manufacturing, quality inspection and product sales, and specialize in the development and production of various CT voltage current characteristic integrated tester, transformer oil filter, Decolorization Machine. We plan to form an enterprise with strong market development capabilities, scientific research and development capabilities, project operation and maintenance capabilities. The good reputation of the products has established a solid market foundation for the company's development. The spirit of advancing with the times urges us to never stop, relying on the strong strength accumulated over the years, the company is making rapid progress.

1. Application
FTD-6000 Transformer Tan Delta and Capacitance Tester is a new generation test instrument for power industry, which fully automatic on-site measuring dielectric loss (tgδ) and the capacitance (Cx) of electric equipment. It's suitable for testing on transformer, insulating bush, capacitor, CT/PT, MOA etc.

 

It's also called: Automatic Capacitance and Tan Delta Tester, Capacitance and Dissipation Factor Tester, Capacitance & Dissipation Factor Test Set, Capacitance & Dielectric loss (Tan Delta) measuring bridge, Capacitance & Dissipation Factor Measuring Bridge

connection of dielectric loss tester

 

2. Dissipation/Power Factor Measurement (Tan Delta) on Instrument Transformers

An insulation failure is often the reason for an instrument transformer (IT) malfunction.

Factors which possibly accelerate the insulation's aging process:

● Moisture ingression due to broken seals

● Heat caused by the ambient temperature or sunlight

 

Older insulation can lead to high losses in the IT, which generates further heat. Since ITs are not actively cooled, old or degraded insulation can result in a failure or even an explosion. Fragments from the explosion represent a serious hazard for persons in the substation as well as for surrounding equipment.

 

Dissipation/power factor (tan(δ) delta) measurements help you determine the insulation condition. When using our transformer testing systems, you will also be able to determine the dissipation factor at various frequencies and detect any signs of aging at an early stage. Thus, an IT can be replaced before any further damage occurs.

12kv transformer tan delta tester at site

 

3. Technical Parameters

Working condition

-15℃~40℃

RH<80%

Anti-interference principle

Frequency conversion

Power supply

AC 85V~160V

Generator can be used

High voltage output

0.5kV~12kV

Every 0.1kV

Precision

2%

Maximum current

200mA

Capacity

2000VA

Self-excitation power

AC 0V~50V/15A

45HZ/55HZ 47.5HZ/52.5HZ
55HZ/65HZ 57.5HZ/62.5HZ
Automatic double frequency

Resolution

tgδ: 0.001%

Cx: 0.001pF

Accuracy

△tgδ: ±(Reading*1.0%+0.040%)

△Cx: ±(Reading*1.0%+1.00PF)

Measurement range

tgδ

Without limit

Cx

15pF < Cx < 300nF

12kV

Cx < 30 nF

5kV

Cx <150 nF

1kV

Cx <300 nF

CVT test

Cx < 300 nF

CVT ratio range

10~10000

CVT ratio accuracy

0.1%

CVT ratio resolution

0.01

Storage

200 group supports U disk data storage

Dimension

Main unit: 350(L)×270(W)×270(H)

Accessory box: 350(L)×270(W)×160(H)

Weight

Main unit: 22.75kg

Accessory box: 5.25kg

 

4. Features

1). Adaptive lithium batteries or 220 v ac supply. After a single charge, the dc resistance of hundreds of transformers can be tested continuously. The test process is simple and convenient

2). The output current is six grades, the maximum output current is 10A, the maximum output voltage is 25V, and the current can be automatically selected, which is convenient and fast.

3). Wide range and high accuracy,500uΩ~50KΩ.

 

4). It has the function of resistance temperature conversion, and can be equipped with wireless temperature measurement module, which can measure the field test temperature in real time to ensure the accuracy of resistance commutation value.

5). It has many kinds of protection functions, such as back EMF protection, broken line protection, power-off protection and over heating alarm.

 

6). 5.6-inch super industrial high-brightness color LCD screen, still visible under strong sunlight.

7). Equipped with external printer, facilitate data printing

8). It can be stored locally and on USB memory.

 

5. Stocks at office

12kv transformer tan delta tester in stock (2)

 

6. Packing, Delivery, Shipping and Payment

deliver fuootech dielectric loss tester (2)

 

7. Certificates

FUOOTECH Inductive load Dc resistance tachometer certificate_

 

8. FAQ

Q1. Are you a manufacturer, trading company or a third party? When and where did your factory established?

FUOOTECH: We are a manufacturer established since 2002, located at Chongqing city, China.

 

Q2: Can you produce your products as our requirements, such as put on our logo?
FUOOTECH: Yes, OEM and ODM are available. We have the professional technical team to design the products as per your request.

Q3. What's the minimum order quantity?
FUOOTECH: 1 Set.

Q4. Will the products be tested before shipping?
FUOOTECH: Yes, of course. QC personal will have a strict testing procedure to all the products before shipping.

fuootech W.jpg

Our company keeps up with the changes of technology, market and user demand, and constantly develops innovative 10kv/12kv Transformer Capacitance Tan Delta Test Set Transformer Capacitance Dissipation Factor Tester 1 Transformer Testing Machine. All over the world efficient network purchase and sale way, to provide you with convenient and fast service. Be sure to come to feel free to get in touch with us in case you need any additional assistance.

Hot Tags: automatic anti-interference transformer tan delta and capacitance tester, China, suppliers, manufacturers, customized, price, in stock, buy discount, Decolorization Machine, transformer oil regeneration, oil water separator, Oil Water Content PPM Tester, high voltage cable hipot tester, lube oil purifier