30kv 50kv 60kv 80kv Ultra Low Frequency High Voltage Generator

VLF stands for Very Low Frequency. VLF is generally considered to be 0.1 Hz and lower, its major application is for testing solid dielectric cable, transformers, motors, generators, switchgear and other electrical apparatus.
Send Inquiry

Product Introduction

We continue to carry out technological innovation, develop safe and effective high-quality oil filtration, transformer oil filtration, oil flushing equipment, and realize brand value and market value for customers. With the social and economic pace, we will continue to carry forward the spirit of 'high quality, efficiency, innovation, integrity', and stick to the operating principle of 'credit first, customer first, quality excellent'. We keep making progress and strive for the development and prosperity of the enterprise. An excellent enterprise culture is the spirit of our company development and success of our business. Let us work together, shoulder to shoulder, and create the future together. We adhere to the coordinated development of goal, organization and behavior, and gather strength to create the maximum value.

1. Application
VLF stands for Very Low Frequency. VLF is generally considered to be 0.1 Hz and lower, its major application is for testing solid dielectric cable, transformers, motors, generators, switchgear and other electrical apparatus.

 

A VLF hipot is just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 50/60Hz. Although the frequency is very low, it is still an alternating current with polarity reversals every half cycle. At 0.1 Hz output, rather than 60Hz, it takes 600 times less current and power to apply an AC voltage to a capacitive load, like a long cable.

0.1Hz Ultra low frequency high voltage generator (2)

 

2. Hipot Testing using VLF (Very Low Frequency) Technology for Power Cables

 

VLF hipot and VLF testing is as simple as just an AC hipot on lower frequency output (at 0.1 Hz). The only way to field test high capacitance loads with AC voltage, like cables and motors/generators, is to use a VLF AC hipot. Lower the frequency, Lower will be the current and power needed to test high capacitive loads.

 

The reason it has not been widely used for more than 4 ~ 5 years is because only in the last 5 ~ 10 years has it been determined that DC voltage testing damages solid dielectric cable and is an ineffective means of determining insulation quality.

 

The IEEE/EPRI/CEA and other world engineering bodies recommended VLF test level for solid dielectric cable is up to three times (3Vo) line to ground voltage for 15 + minutes. For example, A 15 kV cable system, with line to ground voltage up to 7.2kV, is to be performed at 22kV.

 

Many utilities companies do nothing in terms of testing their underground cables and let them fail resulting in necessary emergency repairs, long outages, loss of consumption revenue and annoyed customers. VLF is useful tool to remove or repair the faulty part of the cable in planned shutdown to avoid or overcome any unwanted situation.

80kv AC Vlf High voltage tester at site (2)

 

3. Technical Parameters

Peak voltage:

80kV

Output frequency:

0.1Hz, 0.05Hz and 0.02 Hz (selectable)

Fuse:

20A

Maximum load capacity:

1.1μF@0.1Hz, 2.2μF@0.05Hz, 5.5μF@0.02Hz

Measurement accuracy:

3%

Voltage positive and negative peak error:

≤3%

Voltage waveform distortion:

≤5%.

Working environment:

Temperature: -10ºC ~ +50ºC, 85%RH.

Indoor or outdoor

Weight:

Control unit:4kg
HV unit: 50kg

Power supply:

220V ±10%, 50Hz ±5%

If using a portable generator, make sure the output voltage and frequency are stable. Power >3kW.

 

4. More Technical Data for Various Models

Model

Rated voltage

Load capacity

Fuse

Weight

Purpose

FTAC-VLF-30/1.1

30kV
(peak)

0.1Hz ≤1.1µF

10A

Controller:4kg
Booster:25kg

10KV and below voltage
cable, generator

0.05Hz ≤2.2µF

0.02Hz ≤5.5µF

FTAC-VLF-40/1.1

40kV
(peak)

0.1Hz ≤1.1µF

10A

controller:4kg
Booster:40kg

13KV and below voltage
cable, generator

0.05Hz ≤2.2µF

0.02Hz ≤5.5µF

FTAC-VLF-50/1.1

50kV
(peak)

0.1Hz ≤1.1µF

20A

Controller:4kg
Booster:45kg

15.75KV and below
voltage cable, generator

0.05Hz ≤2.2µF

0.02Hz ≤5.5µF

FTAC-VLF-60/1.1

60kV
(peak)

0.1Hz ≤1.1µF

20A

Controller: 4 kg
Booster:50 kg

18KVand below voltage
cable, generator

0.05Hz ≤2.2µF

0.02Hz ≤5.5µF

FTAC-VLF-80/1.1

80kV (Peak)

0.1Hz ≤1.1µF

20A

Controller: 4 kg
Booster:50 kg

35KV and below voltage
cable, generator

0.05Hz ≤2.2µF

0.02Hz ≤5.5µF

More details on VLF testing 30/40/50/60/70/80/90kV, please contact FUOOTECH, we have professional tech team to design correctly designed products and systems.

 

5. Functions & Features

1). Adapts microprocessor controlled, can realize voltage set-up/down, measuring and protecting automatically. Manual intervention is allowable even during the auto voltage boosting.

2). Portable, small size and light weight, easy to move. It is very convenient for outdoor operation.

3). Large LCD touch screen can display waveform clearly, and test report can be printed via built-in printer.

4). The data of current, voltage, and waveform can be sampled at HV side.
 

5). A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside.

6). Closed-loop negative feedback circuit is adopted. No capacity rising during outputting.

7). Over voltage and current protection: When the output is beyond the limitation, the control unit will shut itself down within 20ms.
 

6. Stocks at office

0.1Hz Ultra low frequency high voltage generator in stocks (2)

 

7. Packing, Delivery, Shipping and Payment

pack 80kv AC Vlf Hipot Test Set (2)

 

8. Certificates

FUOOTECH Inductive load Dc resistance tachometer certificate_

 

9. FAQ

Q1. What's the minimum order quantity?
FUOOTECH: 1 Set.

Q2. Will the products be tested before shipping?
FUOOTECH: Yes, of course. QC personal will have a strict testing procedure to all the products before shipping.

Q3. What's your warranty period?
FUOOTECH: We offer 12 months of warranty for all our products from the date of shipment. Even if the warranty period is expired, we still provide lifelong maintenance, technical service and spare parts supply.

Q4. Can we visit your factory before place the order? Is FAT acceptable?
FUOOTECH: Yes, sure. Welcome to visit us to check our company and products at your free time. FAT is acceptable.

 

Welcome to contact us for your inquiry and order.

fuootech W.jpg

 

Our company strives to establish the corporate image with first-class product quality of the 30kv 50kv 60kv 80kv Ultra Low Frequency High Voltage Generator and business reputation. We hope to create a harmonious and win-win ecological value chain, so that the healthy development of the industry, the confidence of practitioners. Quality&customer first are always our constant pursuit.

Hot Tags: FTAC-VLF-80/1.1 80kVAC VLF Hipot Test Set, China, suppliers, manufacturers, customized, price, in stock, buy discount, Kinematic Viscosity Analyzer, vacuum oil filter machine, 20kv portable digital megohmmeter, tan delta test equipment, Vacuum Pumping and Drying System, automatic Interfacial Tension Tester

Send Inquiry