In order to meet the increasingly complex and changeable processing needs of users, our company pays attention to continuously improving and improving the performance and quality of sf6 analyzer, palm oil processing machine, High Voltage Insulation Testers 15kV. Nowadays, our business cover all around the world, with customers from some well-known enterprises and committed to explore new markets actively. Looking back on the process of our development and growth, we deeply feel that this is an era of co-existence of cooperation and competition. We should always welcome cooperation with an open mind and achieve the win-win goal with our partners. Our company draws lessons from the advanced management concept and mode, actively integrates and innovates, continuously improves the management level and efficiency, and continuously enhances the operation ability.
1. Introduction & Application
FT-YJS-058A Auto Cleaning Type Insulating Oil Dielectric loss and resistivity tester, is designed and manufactured based on GB/T5654-2007 of (Liquid insulating material of relative permittivity, dielectric loss factor and DC resistivity measurements). It is used for measuring dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids.
This Oil Tan Delta Test kit is characterized by integrated structure, and integrates test cell, temperature controller, temperature sensor, dielectric loss test bridge, AC test power, standard capacitor, high resistance meter, DC high voltage source and other major components. The transformer oil tan delta test set adopts full digital technology and all of the intelligent automatic measurement, is equipped with large color screen LCD display, whose each step has prompted the English, the test results can be automatically stored and printed output, so that the operator without professional training will be able to use it proficiently.
2. Why Test Oil Dielectric Loss at High Temperature?
High temperature Tan Delta tests are more sensitive to small changes that occur in oil characteristics. Some ionic contaminants may not be detectable at 25°C but are revealed in the 100°C test. Measuring Tan Delta or Resistivity at two temperatures, e.g., ambient and 90 °C (IEC 60247), as opposed to just one temperature, may provide additional, useful information. For example, obtaining a high Tan Delta test result at ambient and an acceptable Tan Delta test result at a high temperature typically indicates the presence of moisture, since the moisture will evaporate at higher temperatures. Conversely, a high Tan Delta test result at both temperatures (or at higher temperatures only) is often attributed to the presence of contaminants.
3. Technical Parameters
Voltage supply |
AC 220V±10% |
Power frequency |
50Hz/60Hz ±1% |
Measuring range |
|
Capacitance |
5pF~200pF |
Relative Permittivity |
1.000~30.000 |
Dielectric loss factor |
0.00001~100 |
DC Resistivity |
2.5MΩm~20TΩm |
Measuring accuracy |
|
Capacitance |
± (1% of measured value+0.5pF) |
Relative Permittivity |
±1% of measured value |
Dielectric dissipation factor |
± (1% of measured value +0.0001) |
DC Resistivity |
±10% of measured value |
Resolution |
|
Capacitance |
0.01pF |
Relative permittivity |
0.001 |
Dielectric dissipation factor |
0.00001 |
Measured temperature range |
0~125℃ |
Temperature measurement error |
±0.5℃ |
AC Test Voltage (RMS) |
500~2200V Continuously adjustable, frequency 50Hz |
DC Test Voltage |
0~500V Continuously adjustable |
Power consumption |
100W |
Ambient temperature |
0℃~40℃ |
Relative humidity(RH) |
<75% |
Dimensions |
500mm × 360mm × 420mm |
Total weight |
22KG |
4. Functions & Features
1). Oil cup is cleaned automatically and has electrode calibration function.
2). Internal standard capacitor electrode type capacitor, with electrode spacing 2mm.
3). Large-screen LCD, backlight, display is clear. Touch screen operation, more conveniently.
4). More accurate. Testing AC power supply adopts AC - DC - AC conversion method.
5). Equipped with over-voltage, over-current and limit protections.
6). Measured temperature and system clock.
7). Medium frequency induction heating electrode cup and short time uniform heating.
8). Direct measure temperature with probe placed inside the measuring electrode cup.
9). Empty cup self-calibration.
5. Stocks at office
6. Packing, Delivery, Shipping and Payment
7. Certificates
8. Main Accessories
No. |
Item |
Qty |
1 |
Main engine |
1 |
2 |
Oil Cup |
1 |
3 |
Oil tube |
1 |
4 |
Oil cup oil hole |
1 |
5 |
Oil cup observation hole |
1 |
6 |
Dedicated test cable |
1 |
7 |
50ml measuring cylinder |
1 |
8 |
Power line |
1 |
9 |
Fuse pipe |
2 |
10 |
Print paper |
2 |
11 |
Allen wrench(5*30) |
1 |
12 |
Allen wrench(1.5*15) |
1 |
Welcome to visit our website and visit our company, welcome your inquiry and contact.
Relying on mass production and reliable quality, our Auto Insulating Oil Resistivity Dielectric Loss Test Equipment Oil Tan Delta Tester is popular in domestic and international markets and have gained a good reputation from our customers. We have established multiple branches all over the country so that we can get closer to and understand the needs of customers, and respond more quickly to products and after-sales services. In line with the core concept of creating value for society, customers, enterprises and employees, we keep in mind that 'product quality is the survival foundation of an enterprise' and constantly innovate and develop.
Hot Tags: FT-YJS-058A Auto Clean Insulating Oil Dielectric Loss and Resistivity Tester, China, suppliers, manufacturers, customized, price, in stock, buy discount, transformer oil treatment equipment, Interfacial tension test of transformer oil, sf6 gas purity test, insulation characteristics tester, vlf withstand test, oil flushing system