Automated Transformer Oil Gas Chromatograph Detector Insualting Oil Dissolved Gas Analyzer

Automated Transformer Oil Gas Chromatograph Detector Insualting Oil Dissolved Gas Analyzer

GC-2010SD transformer oil spectrum analysis of process design of the system fully in line with the People's Republic of China electric power industry standard DL/T 703-1999< gas content in insulating oil by gas chromatography method in the chromatographic process design.
Send Inquiry

Product Introduction

The vitality of our company's market competition lies in the innovation of our interfacial tension test kit, turbine oil dehydration plant, dielectric strength testing equipment. Under the premise that customers put forward improvement opinions, we will do our best to improve the production process and perfect the products. Our customers are all over the world, so we strive to ensure that our products and services are focused on meeting their growing needs. We aim to offer our customers cost effective solutions at the highest quality from material selection, manufacturing, and distribution.

1. Introduction & Application

GC-2010SD transformer oil spectrum analysis of process design of the system fully in line with the People's Republic of China electric power industry standard DL/T 703-1999< gas content in insulating oil by gas chromatography method in the chromatographic process design. 


This DGA Dissolved Gas Analyzer of Transformer oil is equipped with the provisions. The thermal conductivity detector with high sensitivity and hydrogen flame ionization detector, and a nickel catalyst converter, can be dissolved in transformer oil nine gas components: hydrogen, oxygen, nitrogen, carbon monoxide, carbon dioxide, methane, ethane, ethylene, acetylene measuring. Its performance to meet the requirements of gas insulated DL/T 703-1999< chromatograph oil and gas content in gas chromatography ".

More details of FUOOTECH dga analyzer Gas Chromatography

 

2. Analysis of dissolved gases in insulating oil

Content determination of dissolved gases in insulating oil by gas chromatography is set, the power supply enterprise to judge the oil filled power equipment in the operation of the existence of latent heat, discharge fault, in order to ensure the effective operation of the power grid safety, it is also one of the necessary means of testing equipment for oil-filled electrical equipment manufacturers. GC-2010SD transformer oil chromatographic analysis system using three detector process standard recommend, a sampling can complete component of dissolved gas in insulation oil (including hydrogen, oxygen, methane, ethylene, ethane, acetylene, carbon monoxide and carbon dioxide) full content analysis.

Transformer Oil DGA Dissolved Gas Analyzer working at lab

 

 

3. Technical Parameters

(1) Operation display: 5.7-inch lattice localization color LCD

(2) Temperature control region: 6 Road

(3) Temperature range: Above room temperature 8℃ ~ 450℃, Incremental: 1℃, Accuracy: ±0.1℃

(4) Temperature programmed order number: 16 order

(5) Cheng Sheng rate: 0.1~39℃/min

(6) Gas Control: Mechanical valve control mode, electronic flow controller (EFC) and electronic pressure controller (EPC) method

 

(7) External event: 4 way; Auxiliary control output 4 road.

(8) Injector type: Packed column sample or 10 quantitative sampling valves.

(9) Number of detector: 3; double FID, TCD

(10) The parameters of the Ni conversion furnace: More than 85% or higher; Working temperature 350 ℃

(11) Boot into the sample: manual, automatic optional

 

(12) Communication interface: Ethernet: IEEE802.3

Flame ionization detection (GC-FID).

Detection limit: Mt≤3×10-12g/s (Sixteen alkanes)

Noise:≤5×10-14A;

Drift:≤1×10-13A/30min;

Linearity range: ≥106

Thermal conductivity detector(TCD)

Sensitivity: S≥3500mV•ml/mg(Sixteen alkanes)(1, 2, 4, 8 x magnification optional)

Noise:≤10μV;

Baseline drift:≤30μv/30min

 

4. Stocks at office

Insulating Oil DGA Analysers And Monitors For 9 Gases in stock

 

5. Packing, Delivery, Shipping and Payment

delivery of Oil Dissolved Gas Analyzer (2)

 

6. Certificates

FUOOTECH transformer oil dga test kit certificate

 

7. FAQ

1). What's the MOQ of this Transformer Oil Dissolved Gas Chromatography Device?

A: 1 Set.

 

2). What's the delivery time?

A: Generally, it takes about 10 working days for production and then the delivery will be done timely.

 

3). What's the warranty for this tester?

A: 1 year from the date of shipment.

 

4). What's the delivery method?

A: By train, by air, by sea, by truck, by express, etc.

fuootech W

In our service philosophy, the greatest customer satisfaction is always the first, so we strive to improve the quality of Automated Transformer Oil Gas Chromatograph Detector Insualting Oil Dissolved Gas Analyzer and services. In the process of continuous struggle, we have gradually formed a common business goal and value orientation, and coalesced into a unique corporate culture. In the fierce competitive environment, in order to maximize the value of our company, we continue to integrate its capital flow, logistics, information flow and other resources.

Hot Tags: transformer oil dga dissolved gas analyzer, China, suppliers, manufacturers, customized, price, in stock, buy discount, Vlf High Voltage Generator Withstand Tester, Transformer Oil Kinematic Viscosity Tester, Centrifugal Oil Cleaning Machine, SF6 gas handling plant, vacuum pump system, oil filling machine