The FUOOTECH’s FT-FPC Automatic Closed Flash Point Tester is designed and made as per the National Standard of People’s Republic of China GB/T261-2008; GB/T21615-2008; European standard ASTM-D93, it is an advanced analytical instrument, mainly used to determine the closed flash point of petroleum products.
Send Inquiry

Product Introduction

Our company continues to improve the production process and use of equipment, aiming at continuously improving the quality and performance of sf6 analyzer, portable oil filter, fuel oil purifier system. We follow the principles of "equality and mutual benefit, practicality, variety and common development". Providing customers with satisfactory service is our aim.

1. Introduction & Application
The FUOOTECH's FT-FPC Automatic Closed Flash Point Tester is designed and made as per the National Standard of People's Republic of China GB/T261-2008; GB/T21615-2008; European standard ASTM-D93, it is an advanced analytical instrument, mainly used to determine the closed flash point of petroleum products.

This Automated Closed Cup Flash Point Tester is controlled by microcomputer. It is automatic electronic ignition without the need of gas source. It is reliable and easy to operate with self-test function, high measurement accuracy, good repeatability and stable performance. It is an ideal instrument for closed flash point testing in electrical power, petroleum, chemical, power, environmental protection, railway and scientific research, etc.

accessories of closed cup oil Flash Point Apparatus (2)
 

2. About Flash Point of Transformer Oil

Flash Point is the lowest temperature at which a liquid can form an ignitable mixture in air near the surface of the liquid. The lower the flash point, the easier it is to ignite the material. Nowadays, Flash point is used to say non-volatile or flammable substances whether exit highly volatile or flammable substances, and has been one of the most important parameters for petroleum products transportation, storage, operations, safety management…

 

Flash Point of Transformer Oil is defined as the temperature at which light hydrocarbon present in the transformer oil starts evaporating causing a flash on introduction of source under specified condition. It is an important parameter which must be maintained above 140 degree Celsius.

 

Light hydrocarbons are already present in the transformer oil and gets evaporated under the influence of heat due to electrical stress. Light hydrocarbons are also generated by the degradation of the oil due to aging / heat / electrical stress.

 

Flash Point of new Transformer Oil should be more than 140 degree Celsius. In any case, this temperature should not be allowed to be less than 130 degree Celsius for transformer oil in service.

FT-FPC Closed Cup Transformer Oil Flash Point Tester at site (2)

 

 

3. Technical Parameters

Display

7-inch color touch LCD display screen

Test method

Thermocouple differential detection

Test range

Room temperature ~ 400°C

Repeatability

≤110°C: 2°C

≥110°C: 4°C

Accuracy

When flash point <110℃: ±1℃

When flash point ≥110℃: ±2℃

Reproducibility

≤8°C

Resolution

0.1°C

Temperature Sensor

Platinum resistance (PT100)

Ignition mode

Automatically electronic ignition

Printer

High speed thermal printer

Flash Fire Sensor

Ion detection ring

Cooling mode

Built-in Forced air cooling

Power consumption:

≤350W

Ambient Temperature

10°C ~ 45°C

Relative Humidity

≤85%

Power

AC220V ±10%

Dimension

420*220*290mm

Weight

7.5 kg

 

4. Functions & Features

1). 7-inch industrial color touch screen display, no mechanical contacts, dustproof and waterproof, anti-radio frequency interference, long service life.

2). Equipped with parameter prompt function such as test date and test time.

3). Built-in Germany automatic atmospheric pressure detector: automatic to detect and correct the atmosphere pressure; self-adjust the flash point.

4). Able to store 999 testing data.

5). With imported PT100 sensor for differential detection, automatic correction of system deviation.

6). Cover opening, ignition, detection and printing data are automatically completed.

7). Large-caliber air duct and large air volume fan quickly cools down to shorten the test time.

8). Use built-in battery to ensure that test data can be stored for 5 ~ 8 years even when the external power is off.

9). Built-in high speed thermal printer, quieter, faster and clearer.

 

5. Stocks at office

Automated Closed Cup flash point tester at stock (2)

 

6. Packing, Delivery, Shipping and Payment

flash point analyzer delivery (2)

 

7. Certificates

FUOOTECH Flash Point Apparatus certificate_

 

8. Accessories

1) Main Tester 1 Set

2) Sample cup 1 Pcs

3) AC power cord 1 Set

4) Printing paper 1 Roll

5) Instruction manual 1 Copy

6) Certificate 1 Set

Welcome to visit our website and visit our company, welcome your inquiry and contact.

fuootech W.jpg

 

We goal at becoming considered one of your most trustworthy partners and earning your pleasure for Automatic Cleveland Pensky Martens Close Cup Flash Point Tester for Oil Testing. We will continue to focus on product quality, grasp the foundation of the enterprise's own development and refine the industry. We promote the transformation and upgrading of related industries and expand the space for economic development.

Hot Tags: closed cup transformer oil flash point tester, China, suppliers, manufacturers, customized, price, in stock, buy discount, Oil reconditioning system, light oil filtration equipment, DC Resistance Test Equipment, transformer oil treatment machine, insulation oil purifier system, 0 1Hz Ultra low frequency high voltage generator

Send Inquiry