Superior and superb quality, belief in perfection and never-ending pursuit of excellence have led to a strong overall strength of our Current Transformer and Potential Transformer Analyzer, transformer oil regeneration system, mega insulation resistance tester in the market. Over the years, our company adheres to the tenet and mission of 'what customers need is what we do', and strives to provide every customer with exquisite professional technology. We have established the talent concept of recruiting talents to create great business together and relying on them to develop the company. Our technology and quality start off before the others, brand and service driven together and professional team dedicated manufacturing.
1. Introduction & Application
The FUOOTECH's FT-FPC Automatic Closed Flash Point Tester is designed and made as per the National Standard of People's Republic of China GB/T261-2008; GB/T21615-2008; European standard ASTM-D93, it is an advanced analytical instrument, mainly used to determine the closed flash point of petroleum products.
This Automated Closed Cup Flash Point Tester is controlled by microcomputer. It is automatic electronic ignition without the need of gas source. It is reliable and easy to operate with self-test function, high measurement accuracy, good repeatability and stable performance. It is an ideal instrument for closed flash point testing in electrical power, petroleum, chemical, power, environmental protection, railway and scientific research, etc.
2. About Flash Point of Transformer Oil
Flash Point is the lowest temperature at which a liquid can form an ignitable mixture in air near the surface of the liquid. The lower the flash point, the easier it is to ignite the material. Nowadays, Flash point is used to say non-volatile or flammable substances whether exit highly volatile or flammable substances, and has been one of the most important parameters for petroleum products transportation, storage, operations, safety management…
Flash Point of Transformer Oil is defined as the temperature at which light hydrocarbon present in the transformer oil starts evaporating causing a flash on introduction of source under specified condition. It is an important parameter which must be maintained above 140 degree Celsius.
Light hydrocarbons are already present in the transformer oil and gets evaporated under the influence of heat due to electrical stress. Light hydrocarbons are also generated by the degradation of the oil due to aging / heat / electrical stress.
Flash Point of new Transformer Oil should be more than 140 degree Celsius. In any case, this temperature should not be allowed to be less than 130 degree Celsius for transformer oil in service.
3. Technical Parameters
Display |
7-inch color touch LCD display screen |
Test method |
Thermocouple differential detection |
Test range |
Room temperature ~ 400°C |
Repeatability |
≤110°C: 2°C |
≥110°C: 4°C |
|
Accuracy |
When flash point <110℃: ±1℃ |
When flash point ≥110℃: ±2℃ |
|
Reproducibility |
≤8°C |
Resolution |
0.1°C |
Temperature Sensor |
Platinum resistance (PT100) |
Ignition mode |
Automatically electronic ignition |
Printer |
High speed thermal printer |
Flash Fire Sensor |
Ion detection ring |
Cooling mode |
Built-in Forced air cooling |
Power consumption: |
≤350W |
Ambient Temperature |
10°C ~ 45°C |
Relative Humidity |
≤85% |
Power |
AC220V ±10% |
Dimension |
420*220*290mm |
Weight |
7.5 kg |
4. Functions & Features
1). 7-inch industrial color touch screen display, no mechanical contacts, dustproof and waterproof, anti-radio frequency interference, long service life.
2). Equipped with parameter prompt function such as test date and test time.
3). Built-in Germany automatic atmospheric pressure detector: automatic to detect and correct the atmosphere pressure; self-adjust the flash point.
4). Able to store 999 testing data.
5). With imported PT100 sensor for differential detection, automatic correction of system deviation.
6). Cover opening, ignition, detection and printing data are automatically completed.
7). Large-caliber air duct and large air volume fan quickly cools down to shorten the test time.
8). Use built-in battery to ensure that test data can be stored for 5 ~ 8 years even when the external power is off.
9). Built-in high speed thermal printer, quieter, faster and clearer.
5. Stocks at office
6. Packing, Delivery, Shipping and Payment
7. Certificates
8. Accessories
1) Main Tester 1 Set
2) Sample cup 1 Pcs
3) AC power cord 1 Set
4) Printing paper 1 Roll
5) Instruction manual 1 Copy
6) Certificate 1 Set
Welcome to visit our website and visit our company, welcome your inquiry and contact.
Our company's strong R&D and design capabilities can fully meet the needs of our customers and provide reliable and high-quality Automatic Digital Portable Oil Open/Closed Cup Flash and Fire Point Tester. In the era of knowledge economy, it is very important for our company to have a unique core competitiveness to maintain a sustainable competitive advantage. We continue to create value for our customers through the layout of multiple product lines, an operational network covering multiple regions of the world, and composite operational capabilities.
Hot Tags: closed cup transformer oil flash point tester, China, suppliers, manufacturers, customized, price, in stock, buy discount, oil regeneration machine, dew point analyzer, oil flushing system, Fire resistant Oil Purifier, CT Analyzer, dc winding resistance tester