sales@fuootech.com    +86 13527390908
Cont

Have any Questions?

+86 13527390908

Automatic Load and No Losses Tester Electrical Transformer No-Load with CE ISO9001 Certificates Test Equipment

Automatic Load and No Losses Tester Electrical Transformer No-Load with CE ISO9001 Certificates Test Equipment

FTKZ-50A Transformer On-No Load Characteristics Analyzer is the latest product of FUOOTECH Group.
Send Inquiry

Product Introduction

We use advanced electronic trading systems to make 20kv portable digital megohmmeter, Vacuum Pumping System, Oil water content tester trading investment as convenient as buying and selling stocks, thereby improving transaction efficiency and price transparency. We insist on providing stable employment opportunities for our employees and continuously improving their working environment. We build an inclusive, transparent and open management atmosphere.

1. Introduction & Application

FTKZ-50A Transformer On-No Load Characteristics Analyzer is the latest product of FUOOTECH Group. This transformer on load loss tester adopts the popular ARM processor in this year, with 168M basic frequency and 128m memory, which can be expanded to 4G memory card. Using 7-inch high-definition color touch panel, combined with emwin display interface so as to make the instrument interface being friendly and operated in a simple way, it can be operated through the touchscreen without keyboard. The instrument support database and can be exported through USB disk or transmitted to computer via data wire.

 

The circuit design of this instrument is exquisite and unique, which makes it superior in performance, powerful in function, small in size and light in weight. It can not only be used to test the on-no load parameters of transformer, but also measure the harmonic content and waveform in the field. The instrument can record the test curve of transformer under on-no load condition, then provide reliable basis for transformer fault analysis.

Product details of transformer No load and load loss tester

2. Why On Site Transformer Empty Load Characteristics Tester Load Loss Test of transformer is required?

Energy source in the world especially in the developping and undevelopped countries is more and more short, air pollution is more and more serious, which forwards higher requirement on energy saving of the power transformer. Whenever a power transformer is energized , its core will consume energy and this energy will be in form of heat and it is called no-lead losses, these losses will be always present whether the transformer carries load or not.

Loss measurement of the transformer at low power factor always makes the whole industry confused for many years, therefore it is only solved through procurement from developped country at high price.

 

FUOOTECH developped this Transformer Empty Load Test Bed Power Analyzer under strong support of National Science and Technology Fund after difficult investigation for many years. This high technology product with own intelligent property not only reaches international advanced level for precision measurement at low power factor, its innovative data automatic locking technology is characterized with accurate locking, no artificial interference, which can improve working efficiency tens times.

 

The instrument applies 7.0 inch colourful liquid crystal display screen and the intelligent touching control technology, operation is more convenient.

 

Performance of the instrument is excellent, which is extensively applied in motor and air fan, power, and other industries.

Transformer Empty Load Characteristics Analyzer using at site

3. Technical Parameters

1) Voltage measurement scope: AC 10~1000V

2) Current measurement scope: AC 0.1 ~50 A

3) Measurement accuracy:

Voltage: 0.1%±0.005V (frequency 40~70Hz)

0.5%±0.005V (frequency 70~200Hz)

Current: 0.1%±0.0002A (frequency 40~70Hz)

0.5%±0.0002A (frequency 70~200Hz)

Power: P×0.1%± (U×I×0.02%) ±0.05W (P is power factor, U is reading of voltage effective value, I is reading of current effective value)
 

4) Working power supply: AC220V±10%, 50/60 Hz

5) Working temperature: -20℃~40℃

6) Relative humidity: ≤80%RH no dewing

7) Volume: 360×360×200mm

8) Weight: 12kg

 

4. Functions and Features

1). It can measure voltage, current, angle, power and other electrical parameters, and it also can display the vector diagram of voltage and current, both of the displays are shown clearly and intuitively on the same screen.
2). It can measure the parameters such as no-load loss, load loss and impedance voltage, etc.

3). The instrument has the function of harmonic analysis. It can measure the 1-32 harmonic content of voltage and current applied to transformer and display bar graph as well as voltage and current waveform.

 

4). The on-no characteristic curve under different voltage and current can be recorded automatically during the test process of on-no load condition of transformer, which can be more convenient to analyze the characteristics of transformer and core.
5). With the function of data storage and data browsing, the instrument supports DBF database, and it can store test data or browse test records according to user requirements. The instrument also supports the USB disk export function, you can export the test data through USB disk, and the database supports the excel spreadsheet opening mode, which is convenient for editing, printing or archiving.

6). Operate with 7-inch true color touch screen, the GUI interface, with build-in 128M memory (extensible 4G memory card), it supports English and is easy to operate.
7). It is small in size, light in weight, accurate in measurement, no power off calendar and clock function, so it can store test time at any time.

 

5. Stocks at office

empty load noload loss tester in stocks

6. Packing, Delivery, Shipping and Payment

deliver fuootech Transformer no-load load tester

 

7. Certificates

FUOOTECH empty load noload loss tester certificate

 

8. Packing List

No.

Item

Qty

1

Main engine

1

2

Power line

1

3

Ground lead

1

4

Touch Pen

1

5

Fuse pipe

2

6

Print paper

1

7

Voltage line

1

8

Current line

1

fuootech W.jpg

Our company adheres to the 'customer first, product first' business philosophy, adhere to the principle of customer first to provide customers with quality services and high cost-effective Automatic Load and No Losses Tester Electrical Transformer No-Load with CE ISO9001 Certificates Test Equipment. We always adhere to the principle of quality first, and create a good reputation in terms of product quality, technical guarantee and customer service. We emphasize the seriousness of standardized construction, establishing a set of scientific and reasonable standards to manage the enterprise and regulate the behavior of employees, which is conducive to ensuring the long-term and stable development of the enterprise.

Hot Tags: transformer empty load characteristics analyzer, China, suppliers, manufacturers, customized, price, in stock, buy discount, Lube oil flushing skid, palm oil recycling machine, winding resistance tester, insulating oil acidity test kit, Asphalt Viscosity Test Equipment, SF6 gas handling plant