In order to ensure that each portable oil filtration machine, transformer oil regeneration machine, transformer oil regeneration exceeds customer needs, we use a rigorous quality management system to control every link. We learn to think differently, implement teamwork and fulfill our responsibilities. The value of knowledge to the enterprise and the attitude of employees to the enterprise will determine the fate of an enterprise in the market competition. Our strong technical force, process equipment, strict organization and management. Our meticulous work attitude has been highly praised by all walks of life, experts and scholars.
1. Introduction & Application
FT-YJS-058A Auto Cleaning Type Insulating Oil Dielectric loss and resistivity tester, is designed and manufactured based on GB/T5654-2007 of (Liquid insulating material of relative permittivity, dielectric loss factor and DC resistivity measurements). It is used for measuring dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids.
This Oil Tan Delta Test kit is characterized by integrated structure, and integrates test cell, temperature controller, temperature sensor, dielectric loss test bridge, AC test power, standard capacitor, high resistance meter, DC high voltage source and other major components. The transformer oil tan delta test set adopts full digital technology and all of the intelligent automatic measurement, is equipped with large color screen LCD display, whose each step has prompted the English, the test results can be automatically stored and printed output, so that the operator without professional training will be able to use it proficiently.
2. Why Test Oil Dielectric Loss at High Temperature?
High temperature Tan Delta tests are more sensitive to small changes that occur in oil characteristics. Some ionic contaminants may not be detectable at 25°C but are revealed in the 100°C test. Measuring Tan Delta or Resistivity at two temperatures, e.g., ambient and 90 °C (IEC 60247), as opposed to just one temperature, may provide additional, useful information. For example, obtaining a high Tan Delta test result at ambient and an acceptable Tan Delta test result at a high temperature typically indicates the presence of moisture, since the moisture will evaporate at higher temperatures. Conversely, a high Tan Delta test result at both temperatures (or at higher temperatures only) is often attributed to the presence of contaminants.
3. Technical Parameters
Voltage supply |
AC 220V±10% |
Power frequency |
50Hz/60Hz ±1% |
Measuring range |
|
Capacitance |
5pF~200pF |
Relative Permittivity |
1.000~30.000 |
Dielectric loss factor |
0.00001~100 |
DC Resistivity |
2.5MΩm~20TΩm |
Measuring accuracy |
|
Capacitance |
± (1% of measured value+0.5pF) |
Relative Permittivity |
±1% of measured value |
Dielectric dissipation factor |
± (1% of measured value +0.0001) |
DC Resistivity |
±10% of measured value |
Resolution |
|
Capacitance |
0.01pF |
Relative permittivity |
0.001 |
Dielectric dissipation factor |
0.00001 |
Measured temperature range |
0~125℃ |
Temperature measurement error |
±0.5℃ |
AC Test Voltage (RMS) |
500~2200V Continuously adjustable, frequency 50Hz |
DC Test Voltage |
0~500V Continuously adjustable |
Power consumption |
100W |
Ambient temperature |
0℃~40℃ |
Relative humidity(RH) |
<75% |
Dimensions |
500mm × 360mm × 420mm |
Total weight |
22KG |
4. Functions & Features
1). Oil cup is cleaned automatically and has electrode calibration function.
2). Internal standard capacitor electrode type capacitor, with electrode spacing 2mm.
3). Large-screen LCD, backlight, display is clear. Touch screen operation, more conveniently.
4). More accurate. Testing AC power supply adopts AC - DC - AC conversion method.
5). Equipped with over-voltage, over-current and limit protections.
6). Measured temperature and system clock.
7). Medium frequency induction heating electrode cup and short time uniform heating.
8). Direct measure temperature with probe placed inside the measuring electrode cup.
9). Empty cup self-calibration.
5. Stocks at office
6. Packing, Delivery, Shipping and Payment
7. Certificates
8. Main Accessories
No. |
Item |
Qty |
1 |
Main engine |
1 |
2 |
Oil Cup |
1 |
3 |
Oil tube |
1 |
4 |
Oil cup oil hole |
1 |
5 |
Oil cup observation hole |
1 |
6 |
Dedicated test cable |
1 |
7 |
50ml measuring cylinder |
1 |
8 |
Power line |
1 |
9 |
Fuse pipe |
2 |
10 |
Print paper |
2 |
11 |
Allen wrench(5*30) |
1 |
12 |
Allen wrench(1.5*15) |
1 |
Welcome to visit our website and visit our company, welcome your inquiry and contact.
We strictly control the production process and product quality, provide customers with Automatic Transformer Insulation Oil Dielectric Loss Tester Oil Dielectric Tan Delta Tester Oil Tan Delta and Resistivity Dissipation Factor Tester with satisfactory price performance, and strive to develop new products to meet the changing market demand with the goal of customer needs. The purpose of our company is to generate profits, and the core is to maximize the interests of customers. Our company will do well in export and increase the development of domestic market. We will welcome new and old customers at home and abroad to negotiate with excellent quality, high-quality service and low price.
Hot Tags: FT-YJS-058A Auto Clean Insulating Oil Dielectric Loss and Resistivity Tester, China, suppliers, manufacturers, customized, price, in stock, buy discount, Transformer direct resistance speed meter, oil tan delta tester, insulating oil purifier, 12kv transformer tan delta tester, transformer oil dielectric loss tester, Flash Point test kit