Biobase Advanced Double Fid Detector Transformer Oil Dissolved Gas Analyzer

Biobase Advanced Double Fid Detector Transformer Oil Dissolved Gas Analyzer

GC-2010SD transformer oil spectrum analysis of process design of the system fully in line with the People's Republic of China electric power industry standard DL/T 703-1999< gas content in insulating oil by gas chromatography method in the chromatographic process design.
Send Inquiry

Product Introduction

We will uphold our mission, attach importance to customer needs and technical research, and provide customers with more complete dissolved gas analysis monitor, portable dissolved gas analysis equipment, ultra low frequency AC high voltage generator and solutions. We have a high-quality, dynamic R & D team, and we take great efforts to conduct repetitive tests on our products, just to let our customers use them smoothly. We achieve development with talents, create value with science and technology, win trust from customers with quality and create win-win situation with integrity. In product development and quality control, we take national and international standards as the threshold, and meet consumer demand as the highest standard. All employees of the company are not afraid of competition, and will continue to focus on high-tech strategies and strive to develop.

1. Introduction & Application

GC-2010SD transformer oil spectrum analysis of process design of the system fully in line with the People's Republic of China electric power industry standard DL/T 703-1999< gas content in insulating oil by gas chromatography method in the chromatographic process design. 


This DGA Dissolved Gas Analyzer of Transformer oil is equipped with the provisions. The thermal conductivity detector with high sensitivity and hydrogen flame ionization detector, and a nickel catalyst converter, can be dissolved in transformer oil nine gas components: hydrogen, oxygen, nitrogen, carbon monoxide, carbon dioxide, methane, ethane, ethylene, acetylene measuring. Its performance to meet the requirements of gas insulated DL/T 703-1999< chromatograph oil and gas content in gas chromatography ".

More details of FUOOTECH dga analyzer Gas Chromatography

 

2. Analysis of dissolved gases in insulating oil

Content determination of dissolved gases in insulating oil by gas chromatography is set, the power supply enterprise to judge the oil filled power equipment in the operation of the existence of latent heat, discharge fault, in order to ensure the effective operation of the power grid safety, it is also one of the necessary means of testing equipment for oil-filled electrical equipment manufacturers. GC-2010SD transformer oil chromatographic analysis system using three detector process standard recommend, a sampling can complete component of dissolved gas in insulation oil (including hydrogen, oxygen, methane, ethylene, ethane, acetylene, carbon monoxide and carbon dioxide) full content analysis.

Transformer Oil DGA Dissolved Gas Analyzer working at lab

 

 

3. Technical Parameters

(1) Operation display: 5.7-inch lattice localization color LCD

(2) Temperature control region: 6 Road

(3) Temperature range: Above room temperature 8℃ ~ 450℃, Incremental: 1℃, Accuracy: ±0.1℃

(4) Temperature programmed order number: 16 order

(5) Cheng Sheng rate: 0.1~39℃/min

(6) Gas Control: Mechanical valve control mode, electronic flow controller (EFC) and electronic pressure controller (EPC) method

 

(7) External event: 4 way; Auxiliary control output 4 road.

(8) Injector type: Packed column sample or 10 quantitative sampling valves.

(9) Number of detector: 3; double FID, TCD

(10) The parameters of the Ni conversion furnace: More than 85% or higher; Working temperature 350 ℃

(11) Boot into the sample: manual, automatic optional

 

(12) Communication interface: Ethernet: IEEE802.3

Flame ionization detection (GC-FID).

Detection limit: Mt≤3×10-12g/s (Sixteen alkanes)

Noise:≤5×10-14A;

Drift:≤1×10-13A/30min;

Linearity range: ≥106

Thermal conductivity detector(TCD)

Sensitivity: S≥3500mV•ml/mg(Sixteen alkanes)(1, 2, 4, 8 x magnification optional)

Noise:≤10μV;

Baseline drift:≤30μv/30min

 

4. Stocks at office

Insulating Oil DGA Analysers And Monitors For 9 Gases in stock

 

5. Packing, Delivery, Shipping and Payment

delivery of Oil Dissolved Gas Analyzer (2)

 

6. Certificates

FUOOTECH transformer oil dga test kit certificate

 

7. FAQ

1). What's the MOQ of this Transformer Oil Dissolved Gas Chromatography Device?

A: 1 Set.

 

2). What's the delivery time?

A: Generally, it takes about 10 working days for production and then the delivery will be done timely.

 

3). What's the warranty for this tester?

A: 1 year from the date of shipment.

 

4). What's the delivery method?

A: By train, by air, by sea, by truck, by express, etc.

fuootech W

If you choose us, you will not only get a high-quality Biobase Advanced Double Fid Detector Transformer Oil Dissolved Gas Analyzer that best meets your requirements, but also with our most intimate service. The pursuit of excellence is the internal driving force for the progress of all kinds of work. Therefore, we should always aim to achieve first-class. We closely focus on the requirements of comprehensively strengthening the construction of talent team and talent work, with the core of strengthening the capacity building of talent resources.

Hot Tags: transformer oil dga dissolved gas analyzer, China, suppliers, manufacturers, customized, price, in stock, buy discount, transformer No load and load loss tester, High Voltage Insulation Testers 15kV, Transformer short circuit loss tester, surface tension measuring apparatus, Interfacial Tension Test equipment, vacuum dehydration oil purification system

Send Inquiry