With the spirit of high quality, excellent service and development, we pay attention to details and pursue perfect management concepts to produce CT PT Calibrator, oil purification of transformer, no load load tester with stable and reliable performance. In the future development, we will maintain the spirit of 'gratefulness, integrity, innovation, and transcendence', actively exploring development ideas, increasing technological innovation, and improving quality management. We have won the market for the company with advanced marketing models, scientific management and reliable business reputation. Customer satisfaction is not only our eternal pursuit, but also our eternal promise! We firmly believe that quality creates value. Since the establishment of the company, we have been making continuous progress and constantly improving product categories, services and system solutions. All our employees must abide by the regulations in order to gather strength towards the common management policy and management goals.
1. Introduction
Transformer oil regeneration module ZYD-I developped by FUOOTECH enables complete renewal of used and old transformer oil onsite fulfilling the requirement of IEC 60422 standard.
ZYD-I oil reeneration plant only provides regular oil purification including degassing, drying and particulate removal but also removes acidity, sludge, other soluble oil decay products, and improves color. For special application, the system also can be mounted on a leak proof base or be installed and operated on a trailer.
2. Why Transformer Oil Need be Regenerated?
Most power equipments are using transformer oil for their dielectric properties for cooling, insulating, and protecting the active parts. Transformer oils are highly refined oils that consist mainly of a mixture of hydrocarbons. Over time, oxidation by products start to form in the oil. Increases in oxidation by products result in the increase of acidity (neutralization number) and decrease the interfacial tension of the oil. At this stage, sludge starts to form, and oil is losing its dielectric properties because it is getting old. To prevent further deterioration of oil and possible damage to the active part of the transformer, oil needs to be regenerated.
3. Oil Comparasion Before and After Regeneration
4. Technical Parameters
Item |
Unit |
ZYD-I-30 |
ZYD-I-50 |
ZYD-I-100 |
ZYD-I-150 |
ZYD-I-200 |
ZYD-I-250 |
ZYD-I-300 |
|
Flow rate |
L/h |
1800 |
3000 |
6000 |
9000 |
12000 |
15000 |
18000 |
|
Working vacuum |
MPa |
-0.08~-0.099 |
|||||||
Vacuum pressure |
MPa |
≤0.3 |
|||||||
Temperature range |
℃ |
20~80 |
|||||||
Power |
|
3ph 380V 50Hz(or as need) |
|||||||
Working noise |
dB(A) |
75 |
75 |
75 |
75 |
80 |
80 |
80 |
|
Heating power |
kW |
30 |
30 |
45 |
60 |
75 |
90 |
120 |
|
Total power |
kW |
35.5 |
37.5 |
52.5 |
71.4 |
86.5 |
102.5 |
135 |
|
Oil Inlet/Outlet |
mm |
φ25 |
φ32 |
φ42 |
φ50 |
φ50 |
φ60 |
φ60 |
|
Weight |
Kg |
600 |
800 |
1050 |
1400 |
1800 |
2000 |
2200 |
|
Overall |
Length |
mm |
1050 |
1100 |
1200 |
1450 |
1600 |
1800 |
1900 |
Width |
mm |
750 |
800 |
950 |
950 |
1100 |
1200 |
1200 |
|
Height |
mm |
1350 |
1400 |
1500 |
1650 |
1800 |
1900 |
1900 |
|
Breakdown Voltage |
kV |
≥75 |
|||||||
Moisture content |
PPM |
≤3 |
|||||||
Gas content |
% |
≤0.1 |
|||||||
Impurity size |
micron |
≤1 (no free carbon) |
|||||||
IFT |
dynes/cm |
≥40 |
|||||||
Acid value |
mg KOH/g |
≤ 0.03 |
|||||||
Dielectric loss factors |
tgδ(90℃) |
≤0.001 |
Note: 1. The dimension and weight will be changed with changing of technical specs.
2. All the specs can be customized according to client's requirements.
5. Features
1). For special application, the operation can be controlled by P.L.C (Programmable Logic Controller) .
2). Unique vacuum dehydration, degassification and regeneration system, adopt stereo-evaporation technology. Duplex 3D stereo-evaporation, eliminating the liquid water quickly
3). UK g technology by which the trace water that is show chain, such as dissolved water, can be removed effectively.
4). Advanced infrared liquid-level automatic control system to accomplish fully automatic control.
5). Can be applied for vacuum oiling and drying power transmission equipment.
6). Special additives for depolarization can recover oil color of aged transformer oil to new.
6. Our Main Customers and Partners
7. Packing, Delivery, Shipping and Payment
8. Onsite Projects
9. Certificates
10. Our Pre-sale Services
1) Communicated through email, phone, whatsapp, skype, etc., knowing your actual requirements and demands, remcommend you the most suitable model.
2) Related technical documents and commercial quotation can be sent within 4 hours.
3) We have many standard models in stock so they can be delivered within short time.
4) OEM and ODM order are accepted, Any kind of logo printing or design are available.
5) Good Quality + Factory Price + Quick Response + Reliable Service, is what we are trying best to offer you.
6) All the products are produced by our professional workman and our high-work-effect foreign trade team will solve all your problems from different language, time difference, etc.
The company has been committed to China Made Double Stage High Vacuum Transformer Oil Regeneration System manufacturing and research and development, and has many professionals. We hope to achieve unity, mutual assistance and love within the enterprise and harmonious coexistence. We actively upgrade the comprehensive functions of our products, and strive to develop and launch better and more innovative and practical products.
Hot Tags: double-stage vacuum transformer oil regeneration system, China, suppliers, manufacturers, customized, price, in stock, buy discount, Lube oil flushing skid, diesel oil filtration systems, Megger Megohmmeter, Transformer High Voltage Tester, surface tension measuring apparatus, insulating oil dielectric strength tester