As we always state, your need is our mission, please believe us that we can be your best supplier of On Load Tap Changer transformer oil purifier, digital display insulation resistance tester, Lube oil flushing skid, we would like to cooperate with you for a brilliant future. We provide excellent and professional services to customers, and provide high-quality one-stop product supply services to meet the needs of customers in terms of cost and efficiency. We uphold the service tenet of "sincerity, perfection and science" to achieve the common growth of enterprise, shareholders, customers and partners. Our goods will continue to enhance within the order and look forward to cooperation with you. Our company is based on good faith, we do everything for users, your requirements are our goal and your satisfaction is our wish.
1. Application
FUOOTECH’s FTDC-40A Transformer DC Resistance Testing Equipment is designed for testing the DC resistance of inductance circuit such as power transformer coil, current transformer coil and so on.
This winding resistance test set can check the welding quality of the winding joints and whether the winding have inter-turn short circuits. It can test whether the contact of each position of the voltage tap switch is good, whether the actual position of the tap changer matches the indicated position, whether the lead wire is broken, and the multi-stranded wire is wound in parallel. Whether there is stock breakage, etc.
2. About DC Winding Resistance Test
Large power transformers are very valuable and expensive assets that are key to the operation of the electric power system. This includes generator step-up (GSU) transformers that connect generators to the transmission system.
Many of these transformers are approaching or have already exceeded their expected lifespan. According to a U.S. Department of Energy report in 2012, 70 percent of large power transformers on the power system in the United States were over 25 years old, with the overall average transformer age being 40 years.
With aging infrastructure, the routine maintenance and testing of large power transformers has become increasingly necessary to ensure that the equipment remains in good working condition. GSUs are especially important because a failure results in a loss of generation.
One commonly used transformer test is Direct Current (DC) winding resistance testing. Unless the transformer is intentionally demagnetized following this test, significant residual flux remains in the transformer. When the unit is returned to service, the currents and voltages seen during energization can differ from typical values. These changes in current and voltage have the potential to modify the response of generator and transformer protection relays when the unit is energized for the first time following the testing.
3. Technical Parameters
Item | Parameter | Inaccuracy |
Test Current | <20mA、2.5A、5A、10A、20A、40A | |
Test Range | 50μΩ~500mΩ (40A) | accuracy:±(0.2%+2digit) |
10Ω-20KΩ (<20mA) | accuracy:±(0.5%+2digit) | |
Best Resolution | 0.1μΩ | |
Display | LCD | 4 effective digits for resistance value |
Storage | 1000sets | |
Environmental | Operating Temp.:0℃~40℃ | |
Relative Humidity | <90%RH,non-condensing | |
Power Supply | AC 220V±10V, 50Hz±1 Hz | Fuse 5A |
Max Power | 500W | |
Dimension | 400×225×350(mm) | |
Weight | Instrument Box 15.5KG, Wire Box:6KG |
4. Features
1). Download app (Android) to control instrument completely, upload test data for easy reference.
2). 7-inch high resolution LCD touch screen, easy on-site operation. Good visibility under strong light.
3). New power supply technology with multiple current gears and a wide measurement range. The current can be automatically selected according to the load, which is suitable for DC resistance measurement of medium-sized and large transformers and voltage transformers.
4). A complete and reliable protection system, protect instrument from impact of back EMF.
5). Internal data storage up to 1000 sets.
6). RS232 port and USB Port for data storage and PC communication.
7). Built-in high-speed micro printer.
8). With audible discharge alarm, clear discharge instructions.
5. Stocks at office
6. Packing, Delivery, Shipping and Payment
7. Certificates
8. FAQ
1). When can I get your technical and commercial offer?
FUOOTECH: We usually quote within 4 hours after we get your inquiry.
If you are very urgent to get price, please call us or tell us in your email so that we will regard your inquiry priority.
2. What about the leading time for production?
FUOOTECH: it depends on the order quantity and the product. Usually our leading time is within 7 working days after order confirmed.
3. What are your price terms?
FUOOTECH: We accept EXW,FOB, CFR, CIF, ect. You can choose the one which is the most convenient and cost effective for you.
4. How much will be the Shipping cost and time?
FUOOTECH: It depends on the size & weight of your goods and the method of shipping (by sea/ by air/by Express) and your designated port or airport. We will be grateful if you can spare us some minutes to evaluate the cost based on the information provided.
Welcome to contact us for any inquiry and cooperation.
Our enhancement depends around the sophisticated devices, exceptional talents and repeatedly strengthened technology forces for DC Transformer Winding Resistance Test Set. We are customer-oriented, based on integrity management, adopt a modern logistics supply model, high-tech network service system, based on ISO9001 quality system certification, and seek to establish a sincere partnership with customers to maximize customer benefits. Our enterprise always follows the business philosophy of 'taking the user as the center, regarding the quality as the life', guarantees the excellent quality of the products with the advanced technological conditions, excellent processing equipment, perfect testing facilities and strict quality assurance system.
Hot Tags: 40a transformer dc winding resistance meter, China, suppliers, manufacturers, customized, price, in stock, buy discount, Multi stage vacuum pump, palm oil recycling machine, Oil Acid Value Analyzer, oil acidity test kit, digital DC resistance tester, petroleum products density tester