We seek the common development of customers, enterprises, employees and society, and are committed to making our company competitive in the oil regeneration system, 3 Channel Transformer Winding Resistance Tester, oil breakdown voltage tester industry. The company will actively integrate into the national strategic development and regional economic development layout, sincerely cooperate with domestic and foreign enterprises and all sectors of society, complement each other with advantages, win new development, and create brilliance together. We vigorously implement the strategy of strengthening the enterprise with talents, which provides strong talent support for production and operation and promotes the leapfrog development of the enterprise. We carry out brand operation strategy, so that the company's products have excellent cost performance and efficient and quick service characteristics. With the tenet of 'rigorous and pragmatic, striving for perfection', we strive to create excellent products to meet the needs of new and old customers and jointly develop a broad market.
1. Introduction
Transformer oil regeneration module ZYD-I developped by FUOOTECH enables complete renewal of used and old transformer oil onsite fulfilling the requirement of IEC 60422 standard.
ZYD-I oil reeneration plant only provides regular oil purification including degassing, drying and particulate removal but also removes acidity, sludge, other soluble oil decay products, and improves color. For special application, the system also can be mounted on a leak proof base or be installed and operated on a trailer.
2. Why Transformer Oil Need be Regenerated?
Most power equipments are using transformer oil for their dielectric properties for cooling, insulating, and protecting the active parts. Transformer oils are highly refined oils that consist mainly of a mixture of hydrocarbons. Over time, oxidation by products start to form in the oil. Increases in oxidation by products result in the increase of acidity (neutralization number) and decrease the interfacial tension of the oil. At this stage, sludge starts to form, and oil is losing its dielectric properties because it is getting old. To prevent further deterioration of oil and possible damage to the active part of the transformer, oil needs to be regenerated.
3. Oil Comparasion Before and After Regeneration
4. Technical Parameters
Item |
Unit |
ZYD-I-30 |
ZYD-I-50 |
ZYD-I-100 |
ZYD-I-150 |
ZYD-I-200 |
ZYD-I-250 |
ZYD-I-300 |
|
Flow rate |
L/h |
1800 |
3000 |
6000 |
9000 |
12000 |
15000 |
18000 |
|
Working vacuum |
MPa |
-0.08~-0.099 |
|||||||
Vacuum pressure |
MPa |
≤0.3 |
|||||||
Temperature range |
℃ |
20~80 |
|||||||
Power |
|
3ph 380V 50Hz(or as need) |
|||||||
Working noise |
dB(A) |
75 |
75 |
75 |
75 |
80 |
80 |
80 |
|
Heating power |
kW |
30 |
30 |
45 |
60 |
75 |
90 |
120 |
|
Total power |
kW |
35.5 |
37.5 |
52.5 |
71.4 |
86.5 |
102.5 |
135 |
|
Oil Inlet/Outlet |
mm |
φ25 |
φ32 |
φ42 |
φ50 |
φ50 |
φ60 |
φ60 |
|
Weight |
Kg |
600 |
800 |
1050 |
1400 |
1800 |
2000 |
2200 |
|
Overall |
Length |
mm |
1050 |
1100 |
1200 |
1450 |
1600 |
1800 |
1900 |
Width |
mm |
750 |
800 |
950 |
950 |
1100 |
1200 |
1200 |
|
Height |
mm |
1350 |
1400 |
1500 |
1650 |
1800 |
1900 |
1900 |
|
Breakdown Voltage |
kV |
≥75 |
|||||||
Moisture content |
PPM |
≤3 |
|||||||
Gas content |
% |
≤0.1 |
|||||||
Impurity size |
micron |
≤1 (no free carbon) |
|||||||
IFT |
dynes/cm |
≥40 |
|||||||
Acid value |
mg KOH/g |
≤ 0.03 |
|||||||
Dielectric loss factors |
tgδ(90℃) |
≤0.001 |
Note: 1. The dimension and weight will be changed with changing of technical specs.
2. All the specs can be customized according to client's requirements.
5. Features
1). For special application, the operation can be controlled by P.L.C (Programmable Logic Controller) .
2). Unique vacuum dehydration, degassification and regeneration system, adopt stereo-evaporation technology. Duplex 3D stereo-evaporation, eliminating the liquid water quickly
3). UK g technology by which the trace water that is show chain, such as dissolved water, can be removed effectively.
4). Advanced infrared liquid-level automatic control system to accomplish fully automatic control.
5). Can be applied for vacuum oiling and drying power transmission equipment.
6). Special additives for depolarization can recover oil color of aged transformer oil to new.
6. Our Main Customers and Partners
7. Packing, Delivery, Shipping and Payment
8. Onsite Projects
9. Certificates
10. Our Pre-sale Services
1) Communicated through email, phone, whatsapp, skype, etc., knowing your actual requirements and demands, remcommend you the most suitable model.
2) Related technical documents and commercial quotation can be sent within 4 hours.
3) We have many standard models in stock so they can be delivered within short time.
4) OEM and ODM order are accepted, Any kind of logo printing or design are available.
5) Good Quality + Factory Price + Quick Response + Reliable Service, is what we are trying best to offer you.
6) All the products are produced by our professional workman and our high-work-effect foreign trade team will solve all your problems from different language, time difference, etc.
The combination of our people, Double Stage Vacuum Dielectric Oil Dehydration Machine, Insulation Oil Regeneration Plant, brands and business processes creates a unique value for our company. The superior quality, efficiency and top-of-the-range service allow us to set up new refulgence together with our partners and customers. The company will continue to treat customers as relatives, serve the heart, and will further highlight technological innovation.
Hot Tags: double-stage vacuum transformer oil regeneration system, China, suppliers, manufacturers, customized, price, in stock, buy discount, transformer short circuit tester, transformer oil filter machine, Transformer no load load tester, Lubricating Oil Filtration System, portable oil filter machine, transformer oil testing equipment