More and more companies, including us, have clearly realized that dielectric strength testing equipment, ultra low frequency AC voltage test device, dew point analyzer containing green technology are the only asset for corporate survival and market competition. Corporate style is the work ethic formed in the long-term production and operation activities of the enterprise, and is the external expression of the internal quality of the enterprise. The company continues to introduce mid- to high-end talents to build a professional technical team.
1. Introduction
Transformer oil regeneration module ZYD-I developped by FUOOTECH enables complete renewal of used and old transformer oil onsite fulfilling the requirement of IEC 60422 standard.
ZYD-I oil reeneration plant only provides regular oil purification including degassing, drying and particulate removal but also removes acidity, sludge, other soluble oil decay products, and improves color. For special application, the system also can be mounted on a leak proof base or be installed and operated on a trailer.
2. Why Transformer Oil Need be Regenerated?
Most power equipments are using transformer oil for their dielectric properties for cooling, insulating, and protecting the active parts. Transformer oils are highly refined oils that consist mainly of a mixture of hydrocarbons. Over time, oxidation by products start to form in the oil. Increases in oxidation by products result in the increase of acidity (neutralization number) and decrease the interfacial tension of the oil. At this stage, sludge starts to form, and oil is losing its dielectric properties because it is getting old. To prevent further deterioration of oil and possible damage to the active part of the transformer, oil needs to be regenerated.
3. Oil Comparasion Before and After Regeneration
4. Technical Parameters
Item |
Unit |
ZYD-I-30 |
ZYD-I-50 |
ZYD-I-100 |
ZYD-I-150 |
ZYD-I-200 |
ZYD-I-250 |
ZYD-I-300 |
|
Flow rate |
L/h |
1800 |
3000 |
6000 |
9000 |
12000 |
15000 |
18000 |
|
Working vacuum |
MPa |
-0.08~-0.099 |
|||||||
Vacuum pressure |
MPa |
≤0.3 |
|||||||
Temperature range |
℃ |
20~80 |
|||||||
Power |
|
3ph 380V 50Hz(or as need) |
|||||||
Working noise |
dB(A) |
75 |
75 |
75 |
75 |
80 |
80 |
80 |
|
Heating power |
kW |
30 |
30 |
45 |
60 |
75 |
90 |
120 |
|
Total power |
kW |
35.5 |
37.5 |
52.5 |
71.4 |
86.5 |
102.5 |
135 |
|
Oil Inlet/Outlet |
mm |
φ25 |
φ32 |
φ42 |
φ50 |
φ50 |
φ60 |
φ60 |
|
Weight |
Kg |
600 |
800 |
1050 |
1400 |
1800 |
2000 |
2200 |
|
Overall |
Length |
mm |
1050 |
1100 |
1200 |
1450 |
1600 |
1800 |
1900 |
Width |
mm |
750 |
800 |
950 |
950 |
1100 |
1200 |
1200 |
|
Height |
mm |
1350 |
1400 |
1500 |
1650 |
1800 |
1900 |
1900 |
|
Breakdown Voltage |
kV |
≥75 |
|||||||
Moisture content |
PPM |
≤3 |
|||||||
Gas content |
% |
≤0.1 |
|||||||
Impurity size |
micron |
≤1 (no free carbon) |
|||||||
IFT |
dynes/cm |
≥40 |
|||||||
Acid value |
mg KOH/g |
≤ 0.03 |
|||||||
Dielectric loss factors |
tgδ(90℃) |
≤0.001 |
Note: 1. The dimension and weight will be changed with changing of technical specs.
2. All the specs can be customized according to client's requirements.
5. Features
1). For special application, the operation can be controlled by P.L.C (Programmable Logic Controller) .
2). Unique vacuum dehydration, degassification and regeneration system, adopt stereo-evaporation technology. Duplex 3D stereo-evaporation, eliminating the liquid water quickly
3). UK g technology by which the trace water that is show chain, such as dissolved water, can be removed effectively.
4). Advanced infrared liquid-level automatic control system to accomplish fully automatic control.
5). Can be applied for vacuum oiling and drying power transmission equipment.
6). Special additives for depolarization can recover oil color of aged transformer oil to new.
6. Our Main Customers and Partners
7. Packing, Delivery, Shipping and Payment
8. Onsite Projects
9. Certificates
10. Our Pre-sale Services
1) Communicated through email, phone, whatsapp, skype, etc., knowing your actual requirements and demands, remcommend you the most suitable model.
2) Related technical documents and commercial quotation can be sent within 4 hours.
3) We have many standard models in stock so they can be delivered within short time.
4) OEM and ODM order are accepted, Any kind of logo printing or design are available.
5) Good Quality + Factory Price + Quick Response + Reliable Service, is what we are trying best to offer you.
6) All the products are produced by our professional workman and our high-work-effect foreign trade team will solve all your problems from different language, time difference, etc.
In the current increasingly fierce market competition, our company will continue to strive for perfection, continue to deepen the strength of corporate scientific management, improve the quality of Dust Proof Type Double Stage High Vacuum Dielectric Oil Processing Plant 9000liters/Hour, and provide customers with perfect and enthusiastic after-sales service. We are trying to be on the cutting edge, and we adopt our plans depending on the market trends and customers' needs. By strengthening technology research and development and expanding international and domestic markets, we have made our company a leading company in the industry.
Hot Tags: double-stage vacuum transformer oil regeneration system, China, suppliers, manufacturers, customized, price, in stock, buy discount, Portable Density Tester, CT Analyzer, 5A Transformer DC Resistance Tester, 3 Channel Transformer Winding Resistance Tester, low temperature oil density meter, transformer short circuit tester