Looking back on the past and looking forward to the future, our Flash Point test kit, 2 stage vacuum pump, transformer oil breakdown voltage tester will be market-oriented, survive with quality and develop with reputation. The company has advanced equipment, high technological level, and strong product inspection capabilities. We have been wanting ahead to setting up cooperative associations along with you. We focus on the individual strengths, and strive to create a team atmosphere, the same boat, working together. In the whole manufacturing process, we strictly implement the quality system standards, implement the quality management of all staff, all directions and the whole process, and ensure that every link and every process are effectively controlled.
1. Introduction
The FUOOTECH Series ZYD-R Multi-stage Vacuum Transformer Oil Regeneration Machine has been specially designed for on/off site use to completely purify insulating oils in energized or de-energized transformers even when transformer both below and above 110KV and altitude over 500 meters, as well as purify mutual inductor oil, switch oil and so on. Also it can fill the insulating oil into the transformers on-line and dry the transformer.
The ZYD-R oil regeneration machine machine not only provides regular oil treatment works such as degassing, dehydration and particles removal, but also can remove acidity, sludge, carbon deposits, sulfur, oxidative deterioration matter, hydrocarbons and other soluble oil decay products, improve the oil's dielectric strength value (BDV value), dielectric loss, interfacial tension, acidity, so as to improve the physical & chemical properties comparable to new transformer oil.
This ZYD-R transformer oil regeneration plant equipped with high pumping speed rotary vacuum pump and mechnical booster roots pump can continously working at a extreme high vacuum status so as to faster regenerate the oil to a better value.
2. Why Transformer Oil Need be Regenerated?
Most power equipments are using transformer oil for their dielectric properties for cooling, insulating, and protecting the active parts. Transformer oils are highly refined oils that consist mainly of a mixture of hydrocarbons. Over time, oxidation by products start to form in the oil. Increases in oxidation by products result in the increase of acidity (neutralization number) and decrease the interfacial tension of the oil. At this stage, sludge starts to form, and oil is losing its dielectric properties because it is getting old. To prevent further deterioration of oil and possible damage to the active part of the transformer, oil needs to be regenerated.
The level of contamination differs from transformer to transformer. The ageing process, as well as the utilization of a transformer, make it difficult to determine when and how will oil age to the point that it loses its dielectric properties. Regardless of the level of contamination, oil regeneration always delivers the result required by the IEC 60422 standard for mineral insulating oils in electrical equipment. However, our ZYD-R regeneration technology goes one step further and significantly improves on the values required by the IEC 60422 standard, with the returning oil having properties almost identical to those put into the transformer for the first time.
3. Oil Comparasion Before and After Regeneration
4. Technical Parameters
Item |
Unit |
ZYD-R-30 |
ZYD-R-50 |
ZYD-R-100 |
ZYD-R-150 |
ZYD-R-200 |
ZYD-R-250 |
ZYD-R-300 |
|
Flow rate |
L/h |
1800 |
3000 |
6000 |
9000 |
12000 |
15000 |
18000 |
|
Working vacuum |
MPa |
-0.08~-0.099 |
|||||||
Vacuum pressure |
MPa |
≤0.3 |
|||||||
Temperature range |
℃ |
20~80 |
|||||||
Power |
|
3ph 380V 50Hz(or as need) |
|||||||
Working noise |
dB(A) |
75 |
75 |
75 |
75 |
80 |
80 |
80 |
|
Heating power |
kW |
30 |
30 |
45 |
60 |
75 |
90 |
120 |
|
Total power |
kW |
35.5 |
37.5 |
52.5 |
71.4 |
86.5 |
102.5 |
135 |
|
Oil Inlet/Outlet |
mm |
φ25 |
φ32 |
φ42 |
φ50 |
φ50 |
φ60 |
φ60 |
|
Weight |
Kg |
600 |
800 |
1050 |
1400 |
1800 |
2000 |
2200 |
|
Overall |
Length |
mm |
1050 |
1100 |
1200 |
1450 |
1600 |
1800 |
1900 |
Width |
mm |
750 |
800 |
950 |
950 |
1100 |
1200 |
1200 |
|
Height |
mm |
1350 |
1400 |
1500 |
1650 |
1800 |
1900 |
1900 |
|
Breakdown Voltage |
kV |
≥75 |
|||||||
Moisture content |
PPM |
≤3 |
|||||||
Gas content |
% |
≤0.01 |
|||||||
Impurity size |
micron |
≤1 (no free carbon) |
|||||||
IFT |
dynes/cm |
≥40 |
|||||||
Acid value |
mg KOH/g |
≤ 0.03 |
|||||||
Dielectric loss factors |
tgδ(90℃) |
≤0.001 |
Note: 1. The dimension and weight will be changed with changing of technical specs.
2. All the specs can be customized according to client's requirements.
5. Features
1). Special regeneration filter system installed in numerous columns or tanks where special additives filled in for regenerating the oil by reducing acidity, sludge, carbon deposits, sulfur, oxidative deterioration matter, hydrocarbons, etc. so as to effectively recover the electrical properties of the aging insulating oil.
2). High efficiency in eliminating liquid water content quickly and separating gas/air content fast.
3). FUOOTECH's special technology is used to reduce trace moisture and dissolved water in the transformer oil effectively and thoroughly.
4). Multi-stage Progressive Filter parts ensure the distinctive solid particles & mechanical impurities removal.
5). Special high density indirect heating system that can make the oil contains zero sum of ethyne after the regeneration.
6). Double-saftety oil level controlling system keep oil inlet and outlet quantity balancing while operation fully automatically.
6. Our Main Customers and Partners
7. Packing, Delivery, Shipping and Payment
8. Onsite Projects
9. Certificates
10. Our Sales Services after You Order
1). We will recommend you the most suitable shipping way with lowest cost and prepare the proforma invoice/contract at once.
2). Strictly test the products well, then arrange the fastest delivery at 15 ~ 20 working day after confirming the receipt of your payment
3). Send you the copy of shipping documents by email firstly, courier all the original documents to you without any delay.
4). Keep following the machine's status until you receive the oil regeneration machine.
Since our establishment, we have always adhered to the policy of 'high technology, high quality and high service', and with professional and unique innovative ideas, we have grown rapidly in the industry of Fuootech Single-Stage High Vacuum Transformer Oil Filtration Machine Insulating Oil Treatment Machine for 66kv Transformer in China. We believe that every employee should link his or her efforts to the development of the enterprise and work with heart and soul. We warmly welcome your patronage and will serve our clients both at home and abroad with products of superior quality and excellent service geared to the trend of further development as always.
Hot Tags: multi-stage vacuum transformer oil regeneration system, China, suppliers, manufacturers, customized, price, in stock, buy discount, high voltage Insulation Resistance 20kv Tester, kinematic viscosity test equipment, Density Testing Instrument, Dew point measurement of SF6 gas, vlf test kit, Transformer Capacitance Tan Delta Tester