We have to ensure that our fuel oil purification plant, hydraulic fluid purifier, Multi function Digital Insulation Resistance Tester has unique competitive advantages in order to guarantee sales. The concept of honest management will encourage us to work hard and wholeheartedly to provide more professional and high-level services to our new and old customers. In the future, we will spare no effort to extend and improve the industrial chain, and build a world-class supplier integrating product improvement, R & D, brand building and service.
1. Application
The rapid development of modern industry, the insulation test of high-voltage equipment puts forward higher requirements, and the traditional measurement methods will face severe tests. With the large-scale application practice of optical fiber in intelligent substation, FTIR-10M 10KV insulation resistance tester has good insulation and anti-interference ability, high measurement accuracy, easy miniaturization, and extremely low failure rate, which has received extensive attention. It is widely used to solve the evaluation of electrical insulation quality of large high-voltage transformers, electric motors, generators, long-distance power cables and tubular busbars under high-voltage substation and power plant on-site strong interference.
EPR50C Digital insulation resistance meter consists of medium and large scale integrated circuits. The output power of the watch is large, and the output voltage level is a lot (with 6 voltage levels). Rated insulation test voltage range 250V ~ 10kV, insulation resistance measurement range 0.01MΩ ~ 2000GΩ. DC voltage measurement range 0 ~ 1000V, AC voltage measurement range 0 ~ 750V.
2. Warns before Use This Insulation Resistance Tester?
For safety, before use the instrument must be well earthed, because the measured target connects to high voltage power, and exists power frequency leakage.
Once high voltage has started, do not use manual discharge method to check the instrument. After test, please wait till the instrument completes automatic discharge and automatically returns to zero, then manual discharge can be operated. That is because electrical pulse caused by short-circuit discharge will damage the insulation life of the measured object; if the pulse fleeing into the instrument, will also damage the integrated circuit inside the instrument.
The instrument is designed for HV substations and power plants to test the characteristic of large HV transformer, electric machines and appliances, remote power cable or buried cable and other electrical insulation resistance in strong interference environment. It also can be widely used for testing characteristics of insulation resistance in other area.
3. Technical Parameters
Test Function |
Insulation resistance test, voltage test |
|
Condition |
23°C±5°C,below 75%rh |
|
Rated voltage (V) |
250, 500, 1000, 2500V, 5000V, 10000V |
|
Measuring voltage(V) |
Rated voltage ×(1±10%) |
|
Insulation Resistance Range(GΩ) |
0.01MΩ~2000GΩ, Accuracy: ±3%rdg±5dgt |
|
Insulation Resistance Resolution |
0.01MΩ |
|
DC voltage range |
0~1000V |
Resolution 0.1V |
AC voltage range |
0~750V |
Resolution 0.1V |
Output short circuit current |
≥5mA(10000V) |
|
Absorption Ratio and Polarization Index Measurement |
Have |
|
Power Supply |
12V rechargeable battery |
|
Backlight |
Controllable gray screen backlight, suitable for use in dim places |
|
Display mode |
4-bit large LCD display, gray screen backlight |
|
LCD display size |
108mm×65mm |
|
Instrument size |
227.2mm (L)×227.5mm (W)×153mm (H) |
|
USB interface |
With USB interface, software monitoring, storage data can be uploaded to the computer, save the print |
|
Communication Line |
USB communication line 1PC |
|
Test Line |
High voltage robs red 3meter, high voltage test line black 1.5meter, green 1.5meter |
|
Data Storage |
500 groups, "FULL" symbol indicates that storage is full |
|
Data Review |
Data review function: "READ" symbol display |
|
Overflow Display |
Exceed measurement range overflow function: "OL" symbol display |
|
Alarm Function |
Alarm when the measured value exceeds the alarm setting value |
|
Power Consumption |
Standby: 30mA Max (backlight off) |
|
Turn on backlight: 42mA Max |
||
Measure:300mA Max (backlight off) |
||
Instrument weight |
2720g (including battery) |
|
Battery voltage |
When the battery voltage is low, low battery symbol " " will display |
|
Automatic shut-down |
automatic shutdown after 15 minutes boot |
|
Insulation Resistance |
≥50MΩ (between Measuring line and shell) |
|
Pressure Resistance |
AC3kV/50Hz 1min |
|
Working Temperature and Humidity |
-10℃~+50℃<85%RH |
|
Storage Temperature and Humidity |
-15℃~+55℃<90%RH |
|
Suitable for Safety Regulations |
IEC61010-1, IEC1010-2-31, IEC61557-1,5, IEC60529(IP54), Pollution grade 2, CAT III 300V |
4. Stocks at office
5. Packing, Delivery, Shipping and Payment
6. Certificates
7. FAQ
1). What's the warranty period?
Warranty period is 1 year.
2). What about the leading time for production?
It depends on the order quantity and the product. Usually our leading time is within 7 working days after order confirmed and deposit payment is received.
3). What is your terms of delivery?
EXW, FOB, CFR, CIF all acceptable. You can choose the one which is the most convenient and cost effective for you.
4). How much will be the Shipping cost and time?
This will depend on the size of your goods and the method of shipping (by sea/ by air/by Express) and your designated port or airport. We will be grateful if you can spare us some minutes to evaluate the cost based on the information provided.
Welcome to contact us for your inquiry and order.
Our meticulous and comprehensive service is also an important condition to ensure the quality of our Gd-2306 Portable 10kv Megohm Meter Digital Insulation Tester Megger Insulation Resistance Tester. At present, our company has a group of highly qualified technical personnel and sales team. The company has a group of experienced professional and technical personnel.
Hot Tags: 10kV High Voltage Insulation Resistance Tester, China, suppliers, manufacturers, customized, price, in stock, buy discount, single stage rotary vane vacuum pump, Transformer Oil Kinematic Viscosity Tester, Transformer Oil Acidity Tester, Multi stage vacuum pump, SF6 Gas Analyzer and Recovery System, features comprehensive tester