sales@fuootech.com    +86 13527390908
Cont

Have any Questions?

+86 13527390908

GDPT-103C CVT On-site Capacitance Voltage Transformer Calibrator

GDPT-103C CVT On-site Capacitance Voltage Transformer Calibrator

FTCT-1000A CT/PT Analyzer is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, demagnetization, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load.
Send Inquiry

Product Introduction

Our sales market has expanded from domestic market to overseas market. The performance of our surface tension measuring apparatus, tan delta test of transformer, hydraulic oil purification machine has been gradually in line with the international market. Our company carries out brand management and pursues excellent performance. We pay attention to personnel training and improve service level. We will continue to carry out scientific research and innovation, and continue to provide customers with excellent services. We sincerely welcome customers from all over the world to come to our factory for guidance and consultation. We introduce professional and excellent talents, and gather a sincere team with a good corporate culture.

1. Application
FTCT-1000A CT/PT Analyzer is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, demagnetization, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopt LCD, built-in printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.

controller nd power switch of 1000A Power Frequency CT PT Analyzer (2)

2. Current Transformer (CT)?

A current transformer (CT) is a type of transformer that is used to reduce or multiply an alternating current (AC). It produces a current in its secondary which is proportional to the current in its primary.

 

Current transformers, along with voltage or potential transformers, are instrument transformers. Instrument transformers scale the large values of voltage or current to small, standardized values that are easy to handle for measuring instruments and protective relays. The instrument transformers isolate measurement or protection circuits from the high voltage of the primary system. A current transformer provides a secondary current that is accurately proportional to the current flowing in its primary. The current transformer presents a negligible load to the primary circuit.

 

Current transformers are the current-sensing units of the power system and are used at generating stations, electrical substations, and in industrial and commercial electric power distribution.

CT PT Tester Current Transformer Test Equipment at site

3. Function Table

Current Transformer (CT)

Voltage Transformer (PT)

1. Magnetization Curve

1. Excitation Characteristic Test

2. Transformation Ratio Test

2. Transformation Ratio Test

3. Polarity

3. Polarity

4. 5% and 10% error curve

4. Withstand Test of Power Frequency Alternating Current

5. Current Injecting

5. Degauss

6. Demagnetization

6. Calculation of Knee Point Value

7. Withstand Test of Power Frequency Alternating Current

7. Actual Secondary Load Test

8. Automatic Calculation of Excitation Knee Point Value

8. Resistance Test

9. Actual Secondary Load Test

 

10. Resistance Test

 

 

4. Technical Parameters

Operational Power Supply

AC220V±20V, 50~60Hz

Equipment Power Supply Output Waveform

Sine Wave

Single Tester Output Voltage of Excitation Characteristic

0~2500V

Excitation Output Current

0~20 A

Single machine output current of turns ratio test

0~1000A

CT ratio measurement range

5~25000A/5A(5000A/1A)

PT ratio measurement range

1~500kV

Load Range

5~1000VA

Resistance measurement range

0.1~300Ω

Error

≤0.5%(0.2%*Reading+0.3%*Range)

Operating Temperature

-10℃~+40℃

Relative Humidity

<90RH%

Altitude

≤1000m

Overall Dimension (Length × Width × Height)

400 *200 * 260(mm)

Weight

≤22 Kg

 

5. Features

◆ Support the detection of CT and PT, single machine output voltage 0-2500V, current 0-1000A.

◆ All test items can be completed on a single machine without external auxiliary equipment.

◆ Equipped with micro fast printer, it can print test results directly on site.

◆ Adopt intelligent controller, easy to operate.

◆ Large screen LCD, graphic display interface.
 

◆ Give CT / Pt (excitation) inflection point value automatically according to regulations.

◆ Automatically give 5% and 10% error curves.

◆ 3000 sets of test data can be saved without loss after power failure.

◆ Support u disk to transfer and store data, which can be read through standard PC, and generate test report.

◆ Small and light ≤ 22kg, very convenient for field test.

 

6. Stocks at office

Automatic CT PT Tester in stock (2)

 

7. Packing, Delivery, Shipping and Payment

deliver fuootech Automatic CT PT Tester (2)

 

8. Certificates

FUOOTECH Inductive load Dc resistance tachometer certificate_

 

8. Our Advantages

1) 19 years experience in developping and manufacturing according to related China and internatinoal standards

2) Choose Higher quality raw material from the demostic and worldwide market

3) Own complete and advanced production facilities

4) Has the strict test procedures on raw materials and products from A to Z.

5) Have passed CE, ISO certificates

6) Longer warranty period for all our products (2 Years)

7) Factory Direct Sale, More competitive price

8) Variety types for selection and OEM & ODM are available

 

Welcome to contact us for any inquiry and cooperation.

fuootech W.jpg

We take innovation, excellence, and commitment to our enterprise spirit, and try to provide technical GDPT-103C CVT On-site Capacitance Voltage Transformer Calibrator and enthusiastic service to customers. In the future, we will continue to adhere to the strategy of going out, strengthen cooperation and ecological win-win development. We uphold the 'customer-centered' business philosophy, and constantly improve the ability to meet customer requirements.

Hot Tags: 1000a power frequency ct pt analyzer, China, suppliers, manufacturers, customized, price, in stock, buy discount, transformer oil filtration machine, transformer oil moisture tester, winding dc resistance test equipment, digital wave table digital display table, Vlf High Voltage Generator Withstand Tester, Hydraulic Filter Cart

Send Inquiry