We independently research and develop on the basis of introducing and digesting foreign advanced technology, constantly innovate and forge ahead, and strive to create a domestic first-class flash point analyzer, High Voltage Insulation Testers 15kV, palm oil recycling system brand. We are grateful for the recognition and attention of customers, the support of friends from all walks of life and leaders at all levels. Quality is the life of an enterprise and integrity is the foundation of an enterprise. Our company has always adhered to the business principle of 'honest development and win-win cooperation'. The company is determined to create a charming and soulful service quality with a high-quality cultural quality system.
1. Application
The rapid development of modern industry, the insulation test of high-voltage equipment puts forward higher requirements, and the traditional measurement methods will face severe tests. With the large-scale application practice of optical fiber in intelligent substation, FTIR-10M 10KV insulation resistance tester has good insulation and anti-interference ability, high measurement accuracy, easy miniaturization, and extremely low failure rate, which has received extensive attention. It is widely used to solve the evaluation of electrical insulation quality of large high-voltage transformers, electric motors, generators, long-distance power cables and tubular busbars under high-voltage substation and power plant on-site strong interference.
EPR50C Digital insulation resistance meter consists of medium and large scale integrated circuits. The output power of the watch is large, and the output voltage level is a lot (with 6 voltage levels). Rated insulation test voltage range 250V ~ 10kV, insulation resistance measurement range 0.01MΩ ~ 2000GΩ. DC voltage measurement range 0 ~ 1000V, AC voltage measurement range 0 ~ 750V.
2. Warns before Use This Insulation Resistance Tester?
For safety, before use the instrument must be well earthed, because the measured target connects to high voltage power, and exists power frequency leakage.
Once high voltage has started, do not use manual discharge method to check the instrument. After test, please wait till the instrument completes automatic discharge and automatically returns to zero, then manual discharge can be operated. That is because electrical pulse caused by short-circuit discharge will damage the insulation life of the measured object; if the pulse fleeing into the instrument, will also damage the integrated circuit inside the instrument.
The instrument is designed for HV substations and power plants to test the characteristic of large HV transformer, electric machines and appliances, remote power cable or buried cable and other electrical insulation resistance in strong interference environment. It also can be widely used for testing characteristics of insulation resistance in other area.
3. Technical Parameters
Test Function |
Insulation resistance test, voltage test |
|
Condition |
23°C±5°C,below 75%rh |
|
Rated voltage (V) |
250, 500, 1000, 2500V, 5000V, 10000V |
|
Measuring voltage(V) |
Rated voltage ×(1±10%) |
|
Insulation Resistance Range(GΩ) |
0.01MΩ~2000GΩ, Accuracy: ±3%rdg±5dgt |
|
Insulation Resistance Resolution |
0.01MΩ |
|
DC voltage range |
0~1000V |
Resolution 0.1V |
AC voltage range |
0~750V |
Resolution 0.1V |
Output short circuit current |
≥5mA(10000V) |
|
Absorption Ratio and Polarization Index Measurement |
Have |
|
Power Supply |
12V rechargeable battery |
|
Backlight |
Controllable gray screen backlight, suitable for use in dim places |
|
Display mode |
4-bit large LCD display, gray screen backlight |
|
LCD display size |
108mm×65mm |
|
Instrument size |
227.2mm (L)×227.5mm (W)×153mm (H) |
|
USB interface |
With USB interface, software monitoring, storage data can be uploaded to the computer, save the print |
|
Communication Line |
USB communication line 1PC |
|
Test Line |
High voltage robs red 3meter, high voltage test line black 1.5meter, green 1.5meter |
|
Data Storage |
500 groups, "FULL" symbol indicates that storage is full |
|
Data Review |
Data review function: "READ" symbol display |
|
Overflow Display |
Exceed measurement range overflow function: "OL" symbol display |
|
Alarm Function |
Alarm when the measured value exceeds the alarm setting value |
|
Power Consumption |
Standby: 30mA Max (backlight off) |
|
Turn on backlight: 42mA Max |
||
Measure:300mA Max (backlight off) |
||
Instrument weight |
2720g (including battery) |
|
Battery voltage |
When the battery voltage is low, low battery symbol " " will display |
|
Automatic shut-down |
automatic shutdown after 15 minutes boot |
|
Insulation Resistance |
≥50MΩ (between Measuring line and shell) |
|
Pressure Resistance |
AC3kV/50Hz 1min |
|
Working Temperature and Humidity |
-10℃~+50℃<85%RH |
|
Storage Temperature and Humidity |
-15℃~+55℃<90%RH |
|
Suitable for Safety Regulations |
IEC61010-1, IEC1010-2-31, IEC61557-1,5, IEC60529(IP54), Pollution grade 2, CAT III 300V |
4. Stocks at office
5. Packing, Delivery, Shipping and Payment
6. Certificates
7. FAQ
1). What's the warranty period?
Warranty period is 1 year.
2). What about the leading time for production?
It depends on the order quantity and the product. Usually our leading time is within 7 working days after order confirmed and deposit payment is received.
3). What is your terms of delivery?
EXW, FOB, CFR, CIF all acceptable. You can choose the one which is the most convenient and cost effective for you.
4). How much will be the Shipping cost and time?
This will depend on the size of your goods and the method of shipping (by sea/ by air/by Express) and your designated port or airport. We will be grateful if you can spare us some minutes to evaluate the cost based on the information provided.
Welcome to contact us for your inquiry and order.
Our vision is to strive to build the preferred brand of the GM-10kv Hv Digital Insulation Resistance Tester Adjustment Megohmmeter industry and become the best choice for quality customers and industry elites. We digest and absorb the latest technology, and enhance the core competitiveness of the enterprise to meet the market development and user needs. Our enterprise spirit is the advanced group consciousness formed for a long time by the enterprise in production and operation activities to seek its own survival and development, and recognized by the masses of workers.
Hot Tags: 10kV High Voltage Insulation Resistance Tester, China, suppliers, manufacturers, customized, price, in stock, buy discount, insulating oil purifier, mineral oil purifier, Multi stage Roots pumps, SF6 Refilling and Evacuating device, transformer oil acidity testing kit, oil filtration systems