We pursue the administration tenet of 'Quality is exceptional, Provider is supreme, Name is first', and will sincerely create and share success with all clientele for Oil Purifier, oil thermal vacuum purification system, Transformer vacuum pumping set. We are market-oriented and customer-centered, constantly optimizing the construction of the material supply chain, improving the service system, strengthening management internally and expanding the market externally. Through reform and innovation, we will continue to forge ahead and promote the development of the enterprise itself, so that the enterprise will remain invincible in the market competition of survival of the fittest. We always adhere to the management innovation and efficiency priority, and always adhere to the employee-oriented and result-sharing business philosophy. The purpose of our enterprise operation is not only to make profit for ourselves, but more importantly, to take up the responsibility of rushing to the forefront of the world with technology.
1. Application
FTD-9000 Automatic Transformer Dissipation Factor and Capacitance Tester can effectively find the overall damp, deterioration and partly defects of electrical equipment insulation, which are widely used in electrical manufacturing, electrical equipment installation, handover and preventive testing.
The Anti-interference Transformer Dielectric Loss Tester is used for on-site anti-interference, dielectric loss measurement or laboratory dielectric loss measurement. This test instrument is an integrated structure with built-in dielectric loss bridge, variable variable frequency power supply, test transformer and standard capacitor, etc.. The instrument adopts frequency conversion anti-interference and Fourier transform digital filtering technology, fully automatic and intelligent measurement, and the measurement data is very stable under strong interference. The result of measurement is displayed by large screen display, and the instrument comes with micro printer to print and print test results.
2. What are the Precautions to be taken before carrying out the Transformer Tan Delta Test?
1) The test set is a source of high voltage electrical energy and operator must use all practical safely precautions to prevent contact with energized parts of the test equipment and related circuits.
2) Never connect the test set to energized equipment.
3) The ground cable must be connected first and removed last.
4) The ground terminal of the input supply card (green lead) must be connected to the protective ground (earth) terminal of the line power source.
5) Keep the high voltage plugs free from moisture, dust during installation and operation.
6) Adequate clearance (Min 1 foot i.e. 30 cm) arc maintained between energized conductor and ground to prevent any arc over.
7) It should be ensured that test specimen is de-energized and grounded before making any further connection and no person may come in contact with HV output terminal or any materiel energized by the output.
8) Porcelain of the bushings shall be clean and dry. Remove any dirt or oil with clean dry cloth.
9) Test shall not be carried out when there is condensation on the porcelain. Preferably, tests shall not be carried out when the relative humidity is in excess of 75%.
3. Technical Parameters
Accuracy |
Cx: ±(reading×1%+1pF) |
Anti-interference |
Variable frequency anti-interference, the above accuracy can be reached even under 200% interference. |
Capacitance range |
Internal HV: 3pF~60000pF/12kV 60pF~1.2μF/0.5kV |
tgδ range |
Unlimited, 0.001% resolution, automatic identification for capacitance, inductance and resistance of three tested articles. |
Test current range |
10μA~1A |
Internal HV |
Set voltage range: 0.5~10kV/12kV |
Test frequency |
45, 50, 55Hz single frequency |
External HV |
UST, maximum test current is 1A/ 40~70Hz |
CVT self-excitation low voltage output |
Output voltage 3~50V, output current 3~30A |
Measuring duration |
About 40s, depending on measuring method |
Input power supply |
180V~270VAC, 50Hz/60Hz±1%, supplied by alternating current or generator |
Computer interface |
Standard RS232 interface |
Printer |
WH-A7 mini-type thermal printer |
Operating Temperature |
-10℃~50℃ |
Relative humidity |
<90%, Non-condensing |
Overall dimension |
340×260×270mm |
Weight |
22kg |
4. Features
1). The instrument adopts complex number current method to measure capacitance, dielectric loss and other parameters. The measured result is highly accurate and it is easy to realize automatic measurement.
2). The instrument adopts variable frequency technology to eliminate 50Hz/60Hz power frequency interference. So a reliable data will be reachable even under the strong electromagnetic interference.
3). The instrument adopts large screen LCD . In the process of testing, Chinese menu prompt is visualized and easy to operate.
4). The instrument is easy to operate and the measuring process is controlled by microprocessor. Once a suitable measuring method is selected, the data measurement will complete automatically under the control of microprocessor.
5). The instrument is designed to be an integrated model with reference capacitor and HV power supply in it, enables site test measurement and reduces site wiring.
6). The instrument is equipped with CVT testing function, which can achieve CVT self-exciting testing without external accessories and measure the capacitance and dielectric loss of C1 and C2 by at a time.
7). GST measurement adopts ivddv technology and avoids unstable data provided by previous GST measurement.
8). The instrument provides low voltage shell function of GST. When the bus of 220kV CVT is grounded, Dielectric loss tester can be conducted for C11 without removing 10 kV GST.
9). The instrument has a function of measuring high-voltage dielectric loss. It can carry out dielectric loss test with over 12kV with the help of voltage transformer or series resonance.
10). The instrument has a ground-fault protection function. In case that the instrument is not grounded or grounded incorrectly, the instrument will refuse to enter into normal procedure and output HV. As for the over-current protection function, it will protect the instrument from damage when the tested article is in a short circuit or breakdowns.
11). The instrument has a function of electric shock protection. When the instrument operator suffers an electric shock due to incaution, the instrument will cut off the HV immediately and thus ensure the security of operator.
5. Stocks at office
6. Packing, Delivery, Shipping and Payment
7. Certificates
8. Our Advantages
1) 19 years experience in developping and manufacturing according to related China and internatinoal standards
2) Choose Higher quality raw material from the demostic and worldwide market
3) Own complete and advanced production facilities
4) Has the strict test procedures on raw materials and products from A to Z.
5) Have passed CE, ISO certificates
6) Longer warranty period for all our products (2 Years)
7) Factory Direct Sale, More competitive price
8) Variety types for selection and OEM & ODM are available
Our company takes the responsibility of meeting the multiple needs about the High Accuracy Quality Transformer Tan Delta Meter Portable Dielectric and Loss Tangent with Complete Certificates of our customers and creates value for them as our corporate purpose. On the basis of consolidating quality first, we should also provide better products and services for customers. Let you transform the traditional office procurement into a new one-stop demand with high efficiency and low cost.
Hot Tags: transformer capacitance and tan delta tester, China, suppliers, manufacturers, customized, price, in stock, buy discount, 15kv digital insulation resistance tester, portable lube oil purifier, winding resistance measurement system, kinematic viscosity testing apparatus, SF6 Gas Refilling and Treatment Device, 0 1Hz Ultra low frequency high voltage generator