Our company will adhere to the customer-oriented, application-oriented strategy, and continue to focus on the field of petroleum density test set, filtering transformer oil, cooking oil purification. We uphold the 'professional, dedicated, honest' attitude, and work together with customers and partners to grow and develop together. We have a wealth of practical experience in market planning, channel management and brand operation. We insist on advancing with the times, comprehensively enhance the company's innovation and creativity, core competitiveness and corporate cultural soft power, and promote the healthy and steady development of the company.
1. Application
FTCT-1000A CT/PT Analyzer is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, demagnetization, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopt LCD, built-in printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.
2. Current Transformer (CT)?
A current transformer (CT) is a type of transformer that is used to reduce or multiply an alternating current (AC). It produces a current in its secondary which is proportional to the current in its primary.
Current transformers, along with voltage or potential transformers, are instrument transformers. Instrument transformers scale the large values of voltage or current to small, standardized values that are easy to handle for measuring instruments and protective relays. The instrument transformers isolate measurement or protection circuits from the high voltage of the primary system. A current transformer provides a secondary current that is accurately proportional to the current flowing in its primary. The current transformer presents a negligible load to the primary circuit.
Current transformers are the current-sensing units of the power system and are used at generating stations, electrical substations, and in industrial and commercial electric power distribution.
3. Function Table
Current Transformer (CT) |
Voltage Transformer (PT) |
1. Magnetization Curve |
1. Excitation Characteristic Test |
2. Transformation Ratio Test |
2. Transformation Ratio Test |
3. Polarity |
3. Polarity |
4. 5% and 10% error curve |
4. Withstand Test of Power Frequency Alternating Current |
5. Current Injecting |
5. Degauss |
6. Demagnetization |
6. Calculation of Knee Point Value |
7. Withstand Test of Power Frequency Alternating Current |
7. Actual Secondary Load Test |
8. Automatic Calculation of Excitation Knee Point Value |
8. Resistance Test |
9. Actual Secondary Load Test |
|
10. Resistance Test |
4. Technical Parameters
Operational Power Supply |
AC220V±20V, 50~60Hz |
Equipment Power Supply Output Waveform |
Sine Wave |
Single Tester Output Voltage of Excitation Characteristic |
0~2500V |
Excitation Output Current |
0~20 A |
Single machine output current of turns ratio test |
0~1000A |
CT ratio measurement range |
5~25000A/5A(5000A/1A) |
PT ratio measurement range |
1~500kV |
Load Range |
5~1000VA |
Resistance measurement range |
0.1~300Ω |
Error |
≤0.5%(0.2%*Reading+0.3%*Range) |
Operating Temperature |
-10℃~+40℃ |
Relative Humidity |
<90RH% |
Altitude |
≤1000m |
Overall Dimension (Length × Width × Height) |
400 *200 * 260(mm) |
Weight |
≤22 Kg |
5. Features
◆ Support the detection of CT and PT, single machine output voltage 0-2500V, current 0-1000A.
◆ All test items can be completed on a single machine without external auxiliary equipment.
◆ Equipped with micro fast printer, it can print test results directly on site.
◆ Adopt intelligent controller, easy to operate.
◆ Large screen LCD, graphic display interface.
◆ Give CT / Pt (excitation) inflection point value automatically according to regulations.
◆ Automatically give 5% and 10% error curves.
◆ 3000 sets of test data can be saved without loss after power failure.
◆ Support u disk to transfer and store data, which can be read through standard PC, and generate test report.
◆ Small and light ≤ 22kg, very convenient for field test.
6. Stocks at office
7. Packing, Delivery, Shipping and Payment
8. Certificates
8. Our Advantages
1) 19 years experience in developping and manufacturing according to related China and internatinoal standards
2) Choose Higher quality raw material from the demostic and worldwide market
3) Own complete and advanced production facilities
4) Has the strict test procedures on raw materials and products from A to Z.
5) Have passed CE, ISO certificates
6) Longer warranty period for all our products (2 Years)
7) Factory Direct Sale, More competitive price
8) Variety types for selection and OEM & ODM are available
Welcome to contact us for any inquiry and cooperation.
We plan to reduce the manufacturing cost of Intelligent Transformer Oil Acid Value Tester Acidity Detecting Instrument products through continuous technological innovation and expansion of production scale. Our corporate vision is the direction of the flag that leads us to unite and advance, and the power of belief that inspires all employees to pioneer and innovate. We adhere to the general keynote of seeking progress while maintaining stability, pragmatic and innovative, to achieve more quality growth of the company.
Hot Tags: 1000a power frequency ct pt analyzer, China, suppliers, manufacturers, customized, price, in stock, buy discount, Turns Ratio Test Equipment, Transformer no load load tester, fuel oil purifier system, transformer oil treatment, Transformer direct resistance speed meter, fuel oil purifier