With the continuous development of our business, the sales range of our oil regeneration, fuel oil purifier, transformer ohm meter is getting wider and wider, reaching far away all over the world. With the entrepreneurial spirit of continual truth-seeking, innovation, pioneering and enterprising, we have improved our product competitiveness and market adaptability. On the basis of doing a good job in the domestic market, our company will step into the international market with a never-ending pace. Under the conditions of market economy, service as a commodity also has value, and the degree of user satisfaction is the determining factor of whether the service can produce the greatest value, therefore, we always take user satisfaction as the eternal pursuit. Our company's business philosophy is that the increasing demand of customers is the driving force of our progress.
1. Introduction & Application
FTKZ-50A Transformer On-No Load Characteristics Analyzer is the latest product of FUOOTECH Group. This transformer on load loss tester adopts the popular ARM processor in this year, with 168M basic frequency and 128m memory, which can be expanded to 4G memory card. Using 7-inch high-definition color touch panel, combined with emwin display interface so as to make the instrument interface being friendly and operated in a simple way, it can be operated through the touchscreen without keyboard. The instrument support database and can be exported through USB disk or transmitted to computer via data wire.
The circuit design of this instrument is exquisite and unique, which makes it superior in performance, powerful in function, small in size and light in weight. It can not only be used to test the on-no load parameters of transformer, but also measure the harmonic content and waveform in the field. The instrument can record the test curve of transformer under on-no load condition, then provide reliable basis for transformer fault analysis.
2. Why On Site Transformer Empty Load Characteristics Tester Load Loss Test of transformer is required?
Energy source in the world especially in the developping and undevelopped countries is more and more short, air pollution is more and more serious, which forwards higher requirement on energy saving of the power transformer. Whenever a power transformer is energized , its core will consume energy and this energy will be in form of heat and it is called no-lead losses, these losses will be always present whether the transformer carries load or not.
Loss measurement of the transformer at low power factor always makes the whole industry confused for many years, therefore it is only solved through procurement from developped country at high price.
FUOOTECH developped this Transformer Empty Load Test Bed Power Analyzer under strong support of National Science and Technology Fund after difficult investigation for many years. This high technology product with own intelligent property not only reaches international advanced level for precision measurement at low power factor, its innovative data automatic locking technology is characterized with accurate locking, no artificial interference, which can improve working efficiency tens times.
The instrument applies 7.0 inch colourful liquid crystal display screen and the intelligent touching control technology, operation is more convenient.
Performance of the instrument is excellent, which is extensively applied in motor and air fan, power, and other industries.
3. Technical Parameters
1) Voltage measurement scope: AC 10~1000V
2) Current measurement scope: AC 0.1 ~50 A
3) Measurement accuracy:
Voltage: 0.1%±0.005V (frequency 40~70Hz)
0.5%±0.005V (frequency 70~200Hz)
Current: 0.1%±0.0002A (frequency 40~70Hz)
0.5%±0.0002A (frequency 70~200Hz)
Power: P×0.1%± (U×I×0.02%) ±0.05W (P is power factor, U is reading of voltage effective value, I is reading of current effective value)
4) Working power supply: AC220V±10%, 50/60 Hz
5) Working temperature: -20℃~40℃
6) Relative humidity: ≤80%RH no dewing
7) Volume: 360×360×200mm
8) Weight: 12kg
4. Functions and Features
1). It can measure voltage, current, angle, power and other electrical parameters, and it also can display the vector diagram of voltage and current, both of the displays are shown clearly and intuitively on the same screen.
2). It can measure the parameters such as no-load loss, load loss and impedance voltage, etc.
3). The instrument has the function of harmonic analysis. It can measure the 1-32 harmonic content of voltage and current applied to transformer and display bar graph as well as voltage and current waveform.
4). The on-no characteristic curve under different voltage and current can be recorded automatically during the test process of on-no load condition of transformer, which can be more convenient to analyze the characteristics of transformer and core.
5). With the function of data storage and data browsing, the instrument supports DBF database, and it can store test data or browse test records according to user requirements. The instrument also supports the USB disk export function, you can export the test data through USB disk, and the database supports the excel spreadsheet opening mode, which is convenient for editing, printing or archiving.
6). Operate with 7-inch true color touch screen, the GUI interface, with build-in 128M memory (extensible 4G memory card), it supports English and is easy to operate.
7). It is small in size, light in weight, accurate in measurement, no power off calendar and clock function, so it can store test time at any time.
5. Stocks at office
6. Packing, Delivery, Shipping and Payment
7. Certificates
8. Packing List
No. |
Item |
Qty |
1 |
Main engine |
1 |
2 |
Power line |
1 |
3 |
Ground lead |
1 |
4 |
Touch Pen |
1 |
5 |
Fuse pipe |
2 |
6 |
Print paper |
1 |
7 |
Voltage line |
1 |
8 |
Current line |
1 |
We maintain the ultimate pursuit of product quality and hope to create value for society by manufacturing high quality No Load Losses Test Transformer Load and Noload Loss Tester. We will use rich experience and strict management to cooperate with the company's advanced production equipment. In the pursuit of cooperation and win-win era, we look forward to close cooperation with new and old customers, with all friends to create value together, and share the joy of success.
Hot Tags: transformer empty load characteristics analyzer, China, suppliers, manufacturers, customized, price, in stock, buy discount, Transformer Power Factor Tester, dissolved gas analyzer, high voltage Insulation Resistance 20kv Tester, dew point analyzer, explosion proof oil purifier, variable frequency dielectric loss tester