The initial introduction of our low temperature oil density meter, volt ampere characteristics tester, Offline hydraulic oil filtration systems to the market has been a great success due to our proven technological development. Our company will continue to move forward on the road of providing the most professional consulting and services. We touch our customers with our service and lead the industry with our innovation, realizing the common value-added of our company and customers.
1. Introduction and Application
Series FTY-P Fully Automatic Type Vacuum Turbine Oil Purifier, developed based on FTY Series turbine oil filtration systems and equipped with PLC controlling system, is mainly used for the purification of unqualified steam turbine oil (e.g. ISO–VG–46, 32, 68, 100, etc.), especially for severe emulsified steam turbine oil, it can quickly and effectively destroy the emulsification and separate water, gas and particles from oil. This ensures that the quality of the treated oil reaches the new oil standard and ensures the safe operation of the entire turbine system.
The whole process is controlled by PLC system automatically after push one button.
2. About Turbine Oil
Turbine oil is a lubrication and cooling material commonly used in turbine assemblies, turbine compressors, steam and gas turbines. The oil can be of mineral or synthetic origin.
The main quality parameters of turbine oil are:
* Viscosity corresponding to operation temperature;
* Resistance to oxidation;
* Demulsifying and water resistance;
* Long service life;
* Resistance to foam formation.
However, during long term operation, the metal parts and components of turbine equipment are influenced by air, water and high temperature. Oxidized turbine oil gradually changes color from red to dark and develops an unpleasant odor. Sludge forms in the oil, acidity grows, along with corrosion, foaming and formation of emulsions. The lubricant becomes unusable.
3. Technical Parameters
Item |
Unit |
FTY-P-10 |
FTY-P-20 |
FTY-P-30 |
FTY-P-50 |
FTY-P-100 |
FTY-P-150 |
FTY-P-200 |
FTY-P-300 |
Flow rate |
L/hr |
600 |
1200 |
1800 |
3000 |
6000 |
9000 |
12000 |
18000 |
Working Vacuum Degree |
MPa |
-0.06 ~ -0.095 |
|||||||
Working Pressure |
MPa |
≤ 0.3 |
|||||||
Temperature Range |
℃ |
20 ~ 80 |
|||||||
Power Supply |
|
380 VAC, 3 Phase, 50 Hz (or as per requirement) |
|||||||
Heating power |
kW |
12 |
15 |
24 |
30 |
45 |
60 |
72 |
84 |
Total power |
kW |
14 |
17 |
26 |
33 |
48 |
66 |
81 |
97 |
Inlet/outlet caliber |
mm |
Ф25 |
Ф25 |
Ф25 |
Ф32 |
Ф42 |
Ф42 |
Ф50 |
Ф65 |
Weight |
kg |
400 |
450 |
500 |
600 |
700 |
900 |
1200 |
1550 |
Dimension |
mm |
1280 ×750 ×1450 |
1350 ×900 ×1450 |
1350 ×950 ×1500 |
1400 ×950 ×1600 |
1500 ×1000 ×1650 |
1500 ×1200 ×1800 |
1750 ×1450 ×1950 |
1950 ×1630 ×2090 |
Oil Result after treatment |
Water ≤ 80 PPM |
||||||||
Air/Gas ≤0.1% |
|||||||||
Filtering ≤ 3 micron |
|||||||||
Demulsification Value ≤12 min (GB/F 7305) |
|||||||||
Cleanliness ≤NAS 1638 Grade 5 |
Note: 1. The dimension and weight will be changed with changing of technical specs.
2. All the specs can be customized according to client's requirements.
4. Advantages of Steam Turbine Lube Oil Purifier
1). Equipped with PLC controlling system, making the whole operation fully automatically;
2). Equipped with large-size touch screen, displaying dynamic operation status;
3). Strong capabilities in separating water and demulsification. It easily separates huge volume of water from the oil. With the usage of a strengthened hydrophilic and hydrophobic technology (water separation device and filter elements), it comprehensively alters the interactive performances of the two interfaces between oil and water, and accelerates the activity of small little water molecules, combining them together to form a bigger water molecule big enough to be separated from the oil content. This ensures that the cloudy and emulsifying oil becomes transparent and clear;
4). Strong performance in eliminating impurities. Its filtering material has a composite microporous structure that is corrosion-proof and heat-resistant. This is a durable and lasting device, with long-lasting usage, and the deeply-layered filtering elements within the large surface area are able to filter out the microscopic impurities from the oil content in deeper layers;
5). Has the water-auto-discharge system, without drain the water content manually;
6). On-line oil purification can be carried out connecting with a steam turbine or gas turbine automatically with unattended operation.
5. On Site Project
6. Packing, Delivery, Shipping and Payment
7. Certificates
8. What Problems Will Happen if Turbine Oil Is Polluted
1) Rapidly oxidizes and degrades the oil to form acidic substances and corrode metal contact surfaces;
2) The precipitation of the additive in the oil fails, the thickness of the lubricating film is reduced, and the mechanical wear is increased;
3) Lubrication, cooling, and reduced flow properties accelerate metal surface fatigue
4) Ice crystals formed at low temperatures block components and reduce system rigidity
5) System response is slow and accompanied by irregular motion conduction performance degradation;
6) Higher oil temperature for long time and not cool down;
7) Oil pump and power equipment are damaged by cavitation
Our company chooses the target market and formulates the marketing strategy, explores the market opportunity for our Oil Water Separator Vacuum Turbine Oil Polishing Machine (TY-150), opens up the new market, and effectively improves our economic efficiency. We actively promote high-quality development and strive to build the company into a world class enterprise with international competitiveness! We are running the company through employee training, rigorous internal audits, and a structured and standardized management system.
Hot Tags: fully automatic type vacuum turbine oil purifier, China, suppliers, manufacturers, customized, price, in stock, buy discount, oil filling pump, fuel oil purifier, transformer oil treatment equipment, WINDING Resistance OHMMETERS, transformer evacuation machine, on load tap changer analyzer