Our technical support can start from the product design of the Megger Megohmmeter, Transformer Oil Tester, double stage vacuum transformer oil purifier and continue to the after-sale quality feedback of the final product. We always regard customer needs and satisfaction as our own responsibility, and have established a quality management system to ensure that our brand is recognized and trusted by customers at home and abroad. The company always insists on operating its business with justice and sincerity. Management idea refers to the idea of guiding the production and operation activities of an enterprise according to what kind of business ideas, values, codes of conduct, etc. We always establish a firm sense of social responsibility and carry out extensive and in-depth cooperation in this industry field.
1. Introduction & Application
The FUOOTECH's FT-FPC Automatic Closed Flash Point Tester is designed and made as per the National Standard of People's Republic of China GB/T261-2008; GB/T21615-2008; European standard ASTM-D93, it is an advanced analytical instrument, mainly used to determine the closed flash point of petroleum products.
This Automated Closed Cup Flash Point Tester is controlled by microcomputer. It is automatic electronic ignition without the need of gas source. It is reliable and easy to operate with self-test function, high measurement accuracy, good repeatability and stable performance. It is an ideal instrument for closed flash point testing in electrical power, petroleum, chemical, power, environmental protection, railway and scientific research, etc.
2. About Flash Point of Transformer Oil
Flash Point is the lowest temperature at which a liquid can form an ignitable mixture in air near the surface of the liquid. The lower the flash point, the easier it is to ignite the material. Nowadays, Flash point is used to say non-volatile or flammable substances whether exit highly volatile or flammable substances, and has been one of the most important parameters for petroleum products transportation, storage, operations, safety management…
Flash Point of Transformer Oil is defined as the temperature at which light hydrocarbon present in the transformer oil starts evaporating causing a flash on introduction of source under specified condition. It is an important parameter which must be maintained above 140 degree Celsius.
Light hydrocarbons are already present in the transformer oil and gets evaporated under the influence of heat due to electrical stress. Light hydrocarbons are also generated by the degradation of the oil due to aging / heat / electrical stress.
Flash Point of new Transformer Oil should be more than 140 degree Celsius. In any case, this temperature should not be allowed to be less than 130 degree Celsius for transformer oil in service.
3. Technical Parameters
Display |
7-inch color touch LCD display screen |
Test method |
Thermocouple differential detection |
Test range |
Room temperature ~ 400°C |
Repeatability |
≤110°C: 2°C |
≥110°C: 4°C |
|
Accuracy |
When flash point <110℃: ±1℃ |
When flash point ≥110℃: ±2℃ |
|
Reproducibility |
≤8°C |
Resolution |
0.1°C |
Temperature Sensor |
Platinum resistance (PT100) |
Ignition mode |
Automatically electronic ignition |
Printer |
High speed thermal printer |
Flash Fire Sensor |
Ion detection ring |
Cooling mode |
Built-in Forced air cooling |
Power consumption: |
≤350W |
Ambient Temperature |
10°C ~ 45°C |
Relative Humidity |
≤85% |
Power |
AC220V ±10% |
Dimension |
420*220*290mm |
Weight |
7.5 kg |
4. Functions & Features
1). 7-inch industrial color touch screen display, no mechanical contacts, dustproof and waterproof, anti-radio frequency interference, long service life.
2). Equipped with parameter prompt function such as test date and test time.
3). Built-in Germany automatic atmospheric pressure detector: automatic to detect and correct the atmosphere pressure; self-adjust the flash point.
4). Able to store 999 testing data.
5). With imported PT100 sensor for differential detection, automatic correction of system deviation.
6). Cover opening, ignition, detection and printing data are automatically completed.
7). Large-caliber air duct and large air volume fan quickly cools down to shorten the test time.
8). Use built-in battery to ensure that test data can be stored for 5 ~ 8 years even when the external power is off.
9). Built-in high speed thermal printer, quieter, faster and clearer.
5. Stocks at office
6. Packing, Delivery, Shipping and Payment
7. Certificates
8. Accessories
1) Main Tester 1 Set
2) Sample cup 1 Pcs
3) AC power cord 1 Set
4) Printing paper 1 Roll
5) Instruction manual 1 Copy
6) Certificate 1 Set
Welcome to visit our website and visit our company, welcome your inquiry and contact.
In an ever-changing marketplace, we continue to make new advances every year by offering the best PT-D93-261 Upgraded Pensky-Martens Closed-Cup Flash Point Tester to people. As a good company, excellence in craftsmanship should be the most basic working standard for each and every one of our employees. Our friendship with customers is based on mutual respect, equality and mutual benefit.
Hot Tags: closed cup transformer oil flash point tester, China, suppliers, manufacturers, customized, price, in stock, buy discount, Turns Ratio Test Set, oil tan delta test kit, transformer oil filtration system, used cooking oil purifier, Transformer no load load tester, Transformer Oil Kinematic Viscosity Tester