Our Mini Oil Filter Press Machine, insulation characteristics tester, palm oil recycling machine have been widely praised for their high reliability, high efficiency, high stability, complete functions, high technical content, excellent service and timely delivery. We want to carry forward the factors of success in moving forward and promote dedication, excellence, enterprise, responsibility, integrity, honesty and devotion. We combine professional technology, efficient work and a highly qualified team.
1. Application
VLF (Very Low Frequency) AC Hipot Testers are suitable for testing power cables, transformers, switchgear, rotating machinery and other electrical apparatus.
Ultra Low Frequency Dielectric Strength Test is the alternative way for power frequency voltage withstand test. as we know, it is needed huge capacity testing transformer or a resonant transformer for power frequency voltage withstand test to large generator, cables etc. due to larger electrical capacity of insulating layer. The huge equipment is not only bulky but also expensive and not suitable for use. The electricity sector makes some test to solve the problems.
According to theory and test result from domestic and overseas in the past years, 0.1Hz ultralow frequency voltage withstand test can solve this problems and the advantage is not only got same test results but also the instrument dimensions is small and considerably reduced the weight of it .
2. Performance
FTAC Series VLF Hipot Tester gather together with the advanced technology of modern digital conversion, fully computer control, automated boost, buck, measurement and protection. Human intervention can cared out during the automatic step-up process. The main advantages of this hipot test set includes fully electronic, small sizes and light weight, large-screen LCD (clear and intuitive), print output test report, easy to use. It is designed to fully meet the power industry standards. Mechanical approach are used for modulation and demodulation ultra-low-frequency signals but no standard sine wave, some error of measuring and spark discharge in high-pressure part etc, FTAC Series can overcome the shortcoming of these.
3. Technical Parameters
Model |
FTAC-VLF-90kV |
Peak voltage: |
90kV |
Output frequency: |
0.1Hz, 0.05Hz and 0.02 Hz (selectable) |
Fuse: |
20A |
Maximum load capacity: |
1.1μF@0.1Hz, 2.2μF@0.05Hz, 5.5μF@0.02Hz |
Power supply: |
220V ±10%, 50Hz ±5% (If using a portable generator, make sure the output voltage and frequency are stable. Power >3kW.) |
Output voltage accuracy: |
peak voltage instability ≤1%, frequency instability ≤3%. |
Voltage waveform distortion: |
≤5%. |
Output voltage accuracy: |
peak voltage instability ≤1%, frequency instability ≤3%. |
Working environment: |
indoor or outdoor; -10ºC-+50ºC, 85%RH. |
Weight: |
Control unit 4kg, HV unit I: 10kg, HV unit II: 22kg, Capacitor 2kg. |
4. Functions & Features
1). Data of current and voltage are obtained directly through the sampling of high-pressure side and it is true and accurate.
2). Over-voltage protection: the instrument will shut down to protection within 20 ms when the output voltage is exceeding limiting values of setting.
3). Over-current protection: design for dual protection of high and low voltage, downtime protection can be accurately set in high-pressure side. Shut down to protection times is within 20 ms when the current of low-voltage sides exceeds reacted current.
4). High-voltage output protection resistor design in the body boost and it is no need to additional outside resistor.
5). Closed-loop negative feedback control circuit of high and low voltage.
5. Stocks at office
6. Packing, Delivery, Shipping and Payment
7. Certificates
8. Advantages of This VLF High Voltage Tester
1). Safe Optical isolation technology,
2). Easiest to use Fully automatic microcontroller
3). H/L voltage closed loop negative feedback control
4). Built-in printer
5). Built-in protective resistors
6). True sine wave output
7). Real-time display of actual output waveform
8). Ergonomic, menu guided, large backlit LCD
9). Storage of test results for later retrieval and print.
10). Over voltage and current protected
11). Variable frequency 0.1Hz, 0.05Hz, 0.02 Hz, 0.01Hz (0.01Hz for optional)
12). Data of current, voltage and waveform directly sampled at HV side.
13). AC testing does not degrade good cable insulation
14). Harmful space charges are not injected into the cable insulation
15). No traveling waves are generated during testing
16). Rugged and reliable design less prone to failure from transients
17). Invatation Patent
18). Portable, 1 control unit and 1 booster or 2 boosters (≥ 60KV set)
19). ISO & CE mark.
Welcome to contact us for your inquiry and order.
With the concept of science and technology, innovation and development, we have always engaged in both research and production, aiming to be one of the most professional manufacturer of Top Quality Vlf AC Cable Hipot Test System Hi Pot Testing Machine. We warmly welcome people to call and order. All employees of the company follow the scientific, rigorous and pragmatic corporate style, which has made our products well received by customers for many years.
Hot Tags: AC 90KV Vlf High Voltage Tester, China, suppliers, manufacturers, customized, price, in stock, buy discount, features comprehensive tester, oil flash point analyzer, oil purification machine, 50A Transformer DC Resistance Tester, Portable DC Winding Resistance Tester, tan delta test equipment