Our focus on should be to consolidate and enhance the quality and repair of present products, in the meantime constantly establish new products to meet unique customers' requires for oil tan delta test kit, transformer oil recycling, Transformer Winding Resistance Tester. We implement brand strategy, advocate corporate culture, attach importance to research and development reform, and pursue product quality. We have long-term emphasis on research and development work, and continue to provide innovative products that meet customer requirements. We follow rigorous design standards, relentlessly innovative R&D ideas, the concept of manufacturing excellence and the spirit of never-ending service. We follow the general requirements of supply-side structural reform and adhere to innovation-driven development.
1. Introduction & Application
The FUOOTECH's FT-FPC Automatic Closed Flash Point Tester is designed and made as per the National Standard of People's Republic of China GB/T261-2008; GB/T21615-2008; European standard ASTM-D93, it is an advanced analytical instrument, mainly used to determine the closed flash point of petroleum products.
This Automated Closed Cup Flash Point Tester is controlled by microcomputer. It is automatic electronic ignition without the need of gas source. It is reliable and easy to operate with self-test function, high measurement accuracy, good repeatability and stable performance. It is an ideal instrument for closed flash point testing in electrical power, petroleum, chemical, power, environmental protection, railway and scientific research, etc.
2. About Flash Point of Transformer Oil
Flash Point is the lowest temperature at which a liquid can form an ignitable mixture in air near the surface of the liquid. The lower the flash point, the easier it is to ignite the material. Nowadays, Flash point is used to say non-volatile or flammable substances whether exit highly volatile or flammable substances, and has been one of the most important parameters for petroleum products transportation, storage, operations, safety management…
Flash Point of Transformer Oil is defined as the temperature at which light hydrocarbon present in the transformer oil starts evaporating causing a flash on introduction of source under specified condition. It is an important parameter which must be maintained above 140 degree Celsius.
Light hydrocarbons are already present in the transformer oil and gets evaporated under the influence of heat due to electrical stress. Light hydrocarbons are also generated by the degradation of the oil due to aging / heat / electrical stress.
Flash Point of new Transformer Oil should be more than 140 degree Celsius. In any case, this temperature should not be allowed to be less than 130 degree Celsius for transformer oil in service.
3. Technical Parameters
Display |
7-inch color touch LCD display screen |
Test method |
Thermocouple differential detection |
Test range |
Room temperature ~ 400°C |
Repeatability |
≤110°C: 2°C |
≥110°C: 4°C |
|
Accuracy |
When flash point <110℃: ±1℃ |
When flash point ≥110℃: ±2℃ |
|
Reproducibility |
≤8°C |
Resolution |
0.1°C |
Temperature Sensor |
Platinum resistance (PT100) |
Ignition mode |
Automatically electronic ignition |
Printer |
High speed thermal printer |
Flash Fire Sensor |
Ion detection ring |
Cooling mode |
Built-in Forced air cooling |
Power consumption: |
≤350W |
Ambient Temperature |
10°C ~ 45°C |
Relative Humidity |
≤85% |
Power |
AC220V ±10% |
Dimension |
420*220*290mm |
Weight |
7.5 kg |
4. Functions & Features
1). 7-inch industrial color touch screen display, no mechanical contacts, dustproof and waterproof, anti-radio frequency interference, long service life.
2). Equipped with parameter prompt function such as test date and test time.
3). Built-in Germany automatic atmospheric pressure detector: automatic to detect and correct the atmosphere pressure; self-adjust the flash point.
4). Able to store 999 testing data.
5). With imported PT100 sensor for differential detection, automatic correction of system deviation.
6). Cover opening, ignition, detection and printing data are automatically completed.
7). Large-caliber air duct and large air volume fan quickly cools down to shorten the test time.
8). Use built-in battery to ensure that test data can be stored for 5 ~ 8 years even when the external power is off.
9). Built-in high speed thermal printer, quieter, faster and clearer.
5. Stocks at office
6. Packing, Delivery, Shipping and Payment
7. Certificates
8. Accessories
1) Main Tester 1 Set
2) Sample cup 1 Pcs
3) AC power cord 1 Set
4) Printing paper 1 Roll
5) Instruction manual 1 Copy
6) Certificate 1 Set
Welcome to visit our website and visit our company, welcome your inquiry and contact.
We believe that providing mature, efficient, simple and practical Tpo-3000 Closed Cup Fuel Oil Flash Point Tester is the prerequisite for creating new value. Our company carries out product research and development and production with continuous innovation, provides customers with multi-level value and becomes a reliable professional intelligent partner of customers. We realize the requirements of promotion strategy, continuously enhance the ability of scientific and technological innovation, and solve the technical problems in production operation and operation development.
Hot Tags: closed cup transformer oil flash point tester, China, suppliers, manufacturers, customized, price, in stock, buy discount, transformer No load and load loss tester, portable turbine oil purification system, Oil Decoloring Machine, Water Soluble Acid Analyzer, lube oil purification system, Cleveland Open Flash Point Tester