sales@fuootech.com    +86 13527390908
Cont

Have any Questions?

+86 13527390908

Transformer Oil Dielectric Loss Tester/Oil Resistivity Testing Equipment

Transformer Oil Dielectric Loss Tester/Oil Resistivity Testing Equipment

FT-YJS-058A Auto Cleaning Type Insulating Oil Dielectric loss and resistivity tester, is designed and manufactured based on GB/T5654-2007 of (Liquid insulating material of relative permittivity, dielectric loss factor and DC resistivity measurements).
Send Inquiry

Product Introduction

With the vision of becoming the leader of oil decolorizing equipment, SF6 Gas Refilling and Treatment Device, dielectric testing equipment, we will continue to deliver high-quality products to thousands of customers. Our enterprise spirit of pursuing excellence and keeping improving stimulates the enthusiasm and potential of the enterprise from top to bottom. Our company will give full play to our technical and talent advantages and make due contributions to economic development. We believe that it is our social responsibility to eliminate external concerns and meet the expectations of society.

1. Introduction & Application

FT-YJS-058A Auto Cleaning Type Insulating Oil Dielectric loss and resistivity tester, is designed and manufactured based on GB/T5654-2007 of (Liquid insulating material of relative permittivity, dielectric loss factor and DC resistivity measurements). It is used for measuring dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids.

This Oil Tan Delta Test kit is characterized by integrated structure, and integrates test cell, temperature controller, temperature sensor, dielectric loss test bridge, AC test power, standard capacitor, high resistance meter, DC high voltage source and other major components. The transformer oil tan delta test set adopts full digital technology and all of the intelligent automatic measurement, is equipped with large color screen LCD display, whose each step has prompted the English, the test results can be automatically stored and printed output, so that the operator without professional training will be able to use it proficiently.

oil tan delta and resistivity tester details

2. Why Test Oil Dielectric Loss at High Temperature?

High temperature Tan Delta tests are more sensitive to small changes that occur in oil characteristics. Some ionic contaminants may not be detectable at 25°C but are revealed in the 100°C test. Measuring Tan Delta or Resistivity at two temperatures, e.g., ambient and 90 °C (IEC 60247), as opposed to just one temperature, may provide additional, useful information. For example, obtaining a high Tan Delta test result at ambient and an acceptable Tan Delta test result at a high temperature typically indicates the presence of moisture, since the moisture will evaporate at higher temperatures. Conversely, a high Tan Delta test result at both temperatures (or at higher temperatures only) is often attributed to the presence of contaminants.

transformer oil dielectric loss tester at site

 

 

3. Technical Parameters

Voltage supply

AC 220V±10%

Power frequency

50Hz/60Hz ±1%

Measuring range

Capacitance

5pF~200pF

Relative Permittivity

1.000~30.000

Dielectric loss factor

0.00001~100

DC Resistivity

2.5MΩm~20TΩm

Measuring accuracy

Capacitance

± (1% of measured value+0.5pF)

Relative Permittivity

±1% of measured value

Dielectric dissipation factor

± (1% of measured value +0.0001)

DC Resistivity

±10% of measured value

Resolution

Capacitance

0.01pF

Relative permittivity

0.001

Dielectric dissipation factor

0.00001

Measured temperature range

0~125℃

Temperature measurement error

±0.5℃

AC Test Voltage (RMS)

500~2200V Continuously adjustable, frequency 50Hz

DC Test Voltage

0~500V Continuously adjustable

Power consumption

100W

Ambient temperature

0℃~40℃

Relative humidity(RH)

<75%

Dimensions

500mm × 360mm × 420mm

Total weight

22KG

 

4. Functions & Features

1). Oil cup is cleaned automatically and has electrode calibration function.

2). Internal standard capacitor electrode type capacitor, with electrode spacing 2mm.

3). Large-screen LCD, backlight, display is clear. Touch screen operation, more conveniently.

 

4). More accurate. Testing AC power supply adopts AC - DC - AC conversion method.

5). Equipped with over-voltage, over-current and limit protections.

6). Measured temperature and system clock.

 

7). Medium frequency induction heating electrode cup and short time uniform heating.

8). Direct measure temperature with probe placed inside the measuring electrode cup.

9). Empty cup self-calibration.

 

5. Stocks at office

transformer oil tan delta test kit in stock

 

6. Packing, Delivery, Shipping and Payment

package of oil tan delta and resistivity tester (2)

 

7. Certificates

FUOOTECH Flash Point Apparatus certificate_

 

8. Main Accessories

No.

Item

Qty

1

Main engine

1

2

Oil Cup

1

3

Oil tube

1

4

Oil cup oil hole

1

5

Oil cup observation hole

1

6

Dedicated test cable

1

7

50ml measuring cylinder

1

8

Power line

1

9

Fuse pipe

2

10

Print paper

2

11

Allen wrench(5*30)

1

12

Allen wrench(1.5*15)

1

 

Welcome to visit our website and visit our company, welcome your inquiry and contact.

fuootech W.jpg

 

Our company has won the favor of early users with the Transformer Oil Dielectric Loss Tester/Oil Resistivity Testing Equipment with exquisite production and superior performance, laying the foundation for the company's long-term development. We have laid down a perfect sales network and have stable customer resources. Our company holds the enterprise idea of 'innovation, quality, service', and has won the trust of many users and the reputation in the industry.

Hot Tags: FT-YJS-058A Auto Clean Insulating Oil Dielectric Loss and Resistivity Tester, China, suppliers, manufacturers, customized, price, in stock, buy discount, Acidity Test Kit for Transformer Oil, Decolorization Machine, winding resistance test set, Insulation Resistance Tester, oil flash point analyzer, Vlf High Voltage Generator Withstand Tester

Send Inquiry