The company has a professional technical team and operation team dedicated to the creation of Transformer Oil Kinematic Viscosity Tester, oil acid analyzer, transformer winding resistance testing equipment industry ecosystem, perfecting the industrial chain layout, integrating industry advantages, and promoting the sound development of Transformer Oil Kinematic Viscosity Tester, oil acid analyzer, transformer winding resistance testing equipment industry with high-quality and all-round services. We always insist that innovation is the only way for an enterprise to break through and expand its development space. In the future, we will actively explore the international market under the existing domestic and international markets, and take reputation as the driving force of our production. We know that the quality of an enterprise is directly affected by the quality of its employees, so we insist on absorbing high-quality talents.
1. Introduction & Application
FT-6000C Transformer Load and No Load Loss Tester produced by FUOOTECH Group is mainly used to test capacity, No-load current, No-load loss, short circuit(load) loss, impedance voltage for transformers.
It is small in volume, light in weight, in high accuracy, with steady property, easy to operation can replace the traditional testers. It is displayed by LCD, operated by menu, with friendly interface, is the first choice for all customers.
2. Function & Features
1) Measure the capacity of various distribution transformers, which is convenient and accurate.
2) Measure transformer No-load current, No-load loss, short circuit voltage and short circuit(load) loss.
3) Automatic range switching is carried out inside the instrument, which allows a wide range of voltage and current measurements and simple wiring.
4) When making three phase transformer No-load and load test, the instrument can automatically judge whether the wiring is correct or not, and display the vector diagram of three-phase voltage and current.
5) Finish load test under 1000kVA below distribution transformer full current for single machine. Finish 3150kVA below distribution transformer load test under 1/3 rated current (Under 1/3 rated current, the instrument can be converted to load loss parameters under rated current.)
6) All test results are corrected automatically. The instrument automatic correction as follows, waveform correction, temperature correction, non-rated voltage correction and non-rated current correction. The test results are more accurate.
7) 320*240 high brightness LCD screen, with brightness adjustment. Touch buttons make the operation more convenient.
8) The instrument can preset 40 sets parameters of test objects by users, and these parameters can be deleted and increased at any time according to need, so it is very convenient to use.
9) Real-time clock, recording test date automatically, suitable for storage and management of test results.
10) Built-in panel-type thermal printer, fast print test results.
11) Power down store and browse data (test object settings, measurement results, test time) functions. Store up to 500 groups test results.
12) Allows extended range measurement for external voltage transformer and current transformer. Measure test object of any parameters.
3. Technical Parameters
Environment condition
● Temperature: -5℃-40℃
● Relative humidity: <95% (at 25℃)
● Altitude: <2500m
● No vibration, no ultra-strong electromagnetic field
● Power input: AC220V± 10%, 45-55Hz.
Measurement range
● Internal source:
Current output: 0-10A
Voltage measurement: 0-10V
● Capacity test:
30kVA-2500kVA (for 10kV oil and dry transformers)
50kVA-31500kVA (for 35kV oil transformers)
50kVA-2500kVA (for 20kV dry transformers)
50kVA-2000kVA (for 35kV dry transformers)
● Measurement range of No-load and load tes t(need external voltage regulator, prepared by customer)
Voltage: 0-600V, automatic switching range.
Current: 0-100A, automatic switching range
Frequency: 45-65Hz.
Testing Accuracy
● Voltage: ±0.2%FS at 2-100V; ±0.2% at 100-600V
● Current: ±0.2%FS at 0.5-10A; ±0.2% at 10-100A
● Power: ±0.5% at cosφ>0.1; ±1.0% at 0.02
Insulation strength
● Insulation resistance of Voltage and current input terminal to shell ≥100MOhm
● Withstand voltage between power supply and shell is 2kV RMS, 1mins.
● Dimension: 400*300*220mm
● Weight: 6kg. (accessories are not included.)
4. Stocks at office
5. Packing, Delivery, Shipping and Payment
6. Certificates
7. Our Advantages
1) 19 years experience in developping and manufacturing according to related China
and internatinoal standards
2) Choose Higher quality raw material from the demostic and worldwide market
3) Own complete and advanced production facilities
4) Has the strict test procedures on raw materials and products from A to Z.
5) Have passed CE, ISO certificates
6) Longer warranty period for all our products (2 Years)
7) Factory Direct Sale, More competitive price
8) Variety types for selection and OEM & ODM are available
Welcome to contact us for any inquiry and cooperation.
Our corporate governance is in line with the world's leading enterprises, meanwhile, our Transformer Power Analyzer with Good Price is competitive with leading technology. The company has always adhered to the mid-to-high-end route, and resolutely resisted poor quality and high prices. The company constantly updates equipment and technology, seeks technological breakthroughs, and always ensures punctual delivery.
Hot Tags: ft-6000c transformer load and no load loss tester, China, suppliers, manufacturers, customized, price, in stock, buy discount, Direct Current Resistance Tester, transformer oil filter machine, OLTC oil filtration, transformer oil purification system, transformer on load loss tester, Transformer direct resistance speed meter