We practice the concept of green development and promote the application of new technologies in our Transformer Oil Tester, Oil Dissolved Gas Analyzer, oil acidity test kit. In addition to our own production and R & D advantages, our company also attaches great importance to the construction of sales network and different market positioning directions to meet the requirements of customers in an all-round way. We care about every steps of our services, from factory selection, product development & design, price negotiation, inspection, shipping to aftermarket. All the time, we have been paying attention on all details to insure each product satisfied by our customers.
1. Application
VLF stands for Very Low Frequency. VLF is generally considered to be 0.1 Hz and lower, its major application is for testing solid dielectric cable, transformers, motors, generators, switchgear and other electrical apparatus.
A VLF hipot is just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 50/60Hz. Although the frequency is very low, it is still an alternating current with polarity reversals every half cycle. At 0.1 Hz output, rather than 60Hz, it takes 600 times less current and power to apply an AC voltage to a capacitive load, like a long cable.
2. Hipot Testing using VLF (Very Low Frequency) Technology for Power Cables
VLF hipot and VLF testing is as simple as just an AC hipot on lower frequency output (at 0.1 Hz). The only way to field test high capacitance loads with AC voltage, like cables and motors/generators, is to use a VLF AC hipot. Lower the frequency, Lower will be the current and power needed to test high capacitive loads.
The reason it has not been widely used for more than 4 ~ 5 years is because only in the last 5 ~ 10 years has it been determined that DC voltage testing damages solid dielectric cable and is an ineffective means of determining insulation quality.
The IEEE/EPRI/CEA and other world engineering bodies recommended VLF test level for solid dielectric cable is up to three times (3Vo) line to ground voltage for 15 + minutes. For example, A 15 kV cable system, with line to ground voltage up to 7.2kV, is to be performed at 22kV.
Many utilities companies do nothing in terms of testing their underground cables and let them fail resulting in necessary emergency repairs, long outages, loss of consumption revenue and annoyed customers. VLF is useful tool to remove or repair the faulty part of the cable in planned shutdown to avoid or overcome any unwanted situation.
3. Technical Parameters
Peak voltage: |
80kV |
Output frequency: |
0.1Hz, 0.05Hz and 0.02 Hz (selectable) |
Fuse: |
20A |
Maximum load capacity: |
1.1μF@0.1Hz, 2.2μF@0.05Hz, 5.5μF@0.02Hz |
Measurement accuracy: |
3% |
Voltage positive and negative peak error: |
≤3% |
Voltage waveform distortion: |
≤5%. |
Working environment: |
Temperature: -10ºC ~ +50ºC, 85%RH. |
Indoor or outdoor |
|
Weight: |
Control unit:4kg |
Power supply: |
220V ±10%, 50Hz ±5% |
If using a portable generator, make sure the output voltage and frequency are stable. Power >3kW. |
4. More Technical Data for Various Models
Model |
Rated voltage |
Load capacity |
Fuse |
Weight |
Purpose |
FTAC-VLF-30/1.1 |
30kV |
0.1Hz ≤1.1µF |
10A |
Controller:4kg |
10KV and below voltage |
0.05Hz ≤2.2µF |
|||||
0.02Hz ≤5.5µF |
|||||
FTAC-VLF-40/1.1 |
40kV |
0.1Hz ≤1.1µF |
10A |
controller:4kg |
13KV and below voltage |
0.05Hz ≤2.2µF |
|||||
0.02Hz ≤5.5µF |
|||||
FTAC-VLF-50/1.1 |
50kV |
0.1Hz ≤1.1µF |
20A |
Controller:4kg |
15.75KV and below |
0.05Hz ≤2.2µF |
|||||
0.02Hz ≤5.5µF |
|||||
FTAC-VLF-60/1.1 |
60kV |
0.1Hz ≤1.1µF |
20A |
Controller: 4 kg |
18KVand below voltage |
0.05Hz ≤2.2µF |
|||||
0.02Hz ≤5.5µF |
|||||
FTAC-VLF-80/1.1 |
80kV (Peak) |
0.1Hz ≤1.1µF |
20A |
Controller: 4 kg |
35KV and below voltage |
0.05Hz ≤2.2µF |
|||||
0.02Hz ≤5.5µF |
More details on VLF testing 30/40/50/60/70/80/90kV, please contact FUOOTECH, we have professional tech team to design correctly designed products and systems.
5. Functions & Features
1). Adapts microprocessor controlled, can realize voltage set-up/down, measuring and protecting automatically. Manual intervention is allowable even during the auto voltage boosting.
2). Portable, small size and light weight, easy to move. It is very convenient for outdoor operation.
3). Large LCD touch screen can display waveform clearly, and test report can be printed via built-in printer.
4). The data of current, voltage, and waveform can be sampled at HV side.
5). A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside.
6). Closed-loop negative feedback circuit is adopted. No capacity rising during outputting.
7). Over voltage and current protection: When the output is beyond the limitation, the control unit will shut itself down within 20ms.
6. Stocks at office
7. Packing, Delivery, Shipping and Payment
8. Certificates
9. FAQ
Q1. What's the minimum order quantity?
FUOOTECH: 1 Set.
Q2. Will the products be tested before shipping?
FUOOTECH: Yes, of course. QC personal will have a strict testing procedure to all the products before shipping.
Q3. What's your warranty period?
FUOOTECH: We offer 12 months of warranty for all our products from the date of shipment. Even if the warranty period is expired, we still provide lifelong maintenance, technical service and spare parts supply.
Q4. Can we visit your factory before place the order? Is FAT acceptable?
FUOOTECH: Yes, sure. Welcome to visit us to check our company and products at your free time. FAT is acceptable.
Welcome to contact us for your inquiry and order.
Our company has sufficient spot reserves and according to the market situation and the use of customers, we can use advanced software to track and query the dynamic resource status of re route and scheduled at any time, which can fully meet the timely supply of Very Low Frequency High Voltage Generator AC Hipot Test Device. We have now a expert international trade crew. We always adhere to the business philosophy of "starting from customer demand and ending with customer satisfaction".
Hot Tags: FTAC-VLF-80/1.1 80kVAC VLF Hipot Test Set, China, suppliers, manufacturers, customized, price, in stock, buy discount, low temperature kinematic viscosity tester, portable oil filtration system, Transformer Capacity Tester, 0 1Hz Ultra low frequency high voltage generator, tan delta test equipment, Fire resistant hydraulic oil purifier