Safe production and innovation are the guidelines of every employee in our company, and we will pursue technical innovation relentlessly to promote our Dc Winding Resistance Tester 40A, transformer short circuit tester, offline oil filtration system upgrading and the development of the industry. Integrity is the foundation of our company's development, innovation is the basic support of development and the guarantee of being strong. Talent is the key to the success of the enterprise, is the first resource for the development of the enterprise, excellent talent is the bridge between strategy and implementation, is the prerequisite for the development of the enterprise.
1. Application
VLF (Very Low Frequency) AC Hipot Testers are suitable for testing power cables, transformers, switchgear, rotating machinery and other electrical apparatus.
Ultra Low Frequency Dielectric Strength Test is the alternative way for power frequency voltage withstand test. as we know, it is needed huge capacity testing transformer or a resonant transformer for power frequency voltage withstand test to large generator, cables etc. due to larger electrical capacity of insulating layer. The huge equipment is not only bulky but also expensive and not suitable for use. The electricity sector makes some test to solve the problems.
According to theory and test result from domestic and overseas in the past years, 0.1Hz ultralow frequency voltage withstand test can solve this problems and the advantage is not only got same test results but also the instrument dimensions is small and considerably reduced the weight of it .
2. Performance
FTAC Series VLF Hipot Tester gather together with the advanced technology of modern digital conversion, fully computer control, automated boost, buck, measurement and protection. Human intervention can cared out during the automatic step-up process. The main advantages of this hipot test set includes fully electronic, small sizes and light weight, large-screen LCD (clear and intuitive), print output test report, easy to use. It is designed to fully meet the power industry standards. Mechanical approach are used for modulation and demodulation ultra-low-frequency signals but no standard sine wave, some error of measuring and spark discharge in high-pressure part etc, FTAC Series can overcome the shortcoming of these.
3. Technical Parameters
Model |
FTAC-VLF-90kV |
Peak voltage: |
90kV |
Output frequency: |
0.1Hz, 0.05Hz and 0.02 Hz (selectable) |
Fuse: |
20A |
Maximum load capacity: |
1.1μF@0.1Hz, 2.2μF@0.05Hz, 5.5μF@0.02Hz |
Power supply: |
220V ±10%, 50Hz ±5% (If using a portable generator, make sure the output voltage and frequency are stable. Power >3kW.) |
Output voltage accuracy: |
peak voltage instability ≤1%, frequency instability ≤3%. |
Voltage waveform distortion: |
≤5%. |
Output voltage accuracy: |
peak voltage instability ≤1%, frequency instability ≤3%. |
Working environment: |
indoor or outdoor; -10ºC-+50ºC, 85%RH. |
Weight: |
Control unit 4kg, HV unit I: 10kg, HV unit II: 22kg, Capacitor 2kg. |
4. Functions & Features
1). Data of current and voltage are obtained directly through the sampling of high-pressure side and it is true and accurate.
2). Over-voltage protection: the instrument will shut down to protection within 20 ms when the output voltage is exceeding limiting values of setting.
3). Over-current protection: design for dual protection of high and low voltage, downtime protection can be accurately set in high-pressure side. Shut down to protection times is within 20 ms when the current of low-voltage sides exceeds reacted current.
4). High-voltage output protection resistor design in the body boost and it is no need to additional outside resistor.
5). Closed-loop negative feedback control circuit of high and low voltage.
5. Stocks at office
6. Packing, Delivery, Shipping and Payment
7. Certificates
8. Advantages of This VLF High Voltage Tester
1). Safe Optical isolation technology,
2). Easiest to use Fully automatic microcontroller
3). H/L voltage closed loop negative feedback control
4). Built-in printer
5). Built-in protective resistors
6). True sine wave output
7). Real-time display of actual output waveform
8). Ergonomic, menu guided, large backlit LCD
9). Storage of test results for later retrieval and print.
10). Over voltage and current protected
11). Variable frequency 0.1Hz, 0.05Hz, 0.02 Hz, 0.01Hz (0.01Hz for optional)
12). Data of current, voltage and waveform directly sampled at HV side.
13). AC testing does not degrade good cable insulation
14). Harmful space charges are not injected into the cable insulation
15). No traveling waves are generated during testing
16). Rugged and reliable design less prone to failure from transients
17). Invatation Patent
18). Portable, 1 control unit and 1 booster or 2 boosters (≥ 60KV set)
19). ISO & CE mark.
Welcome to contact us for your inquiry and order.
We believe that providing specific Very Low Frequency Hipot Tester, Vlf Testing Systems to customer satisfaction is an inevitable trend for modern companies to pursue a leading edge in competition. Our company will create more opportunities and a better future for every struggler, and strive to create a fair competition platform and environments. Doing everything with our heart is our consistent attitude, and maximizing customer satisfaction is our constant goal! We believe that as long as we persist and work hard, we will be able to achieve mutual benefit and win-win results with our customers!
Hot Tags: AC 90KV Vlf High Voltage Tester, China, suppliers, manufacturers, customized, price, in stock, buy discount, insulating oil tangent delta tester, online transformer oil filtration, surface tension test equipment, kinematic viscosity unit, volt ampere characteristics tester, turbine oil filtration systems