FTKZ-50A Transformer On-No Load Characteristics Analyzer is the latest product of FUOOTECH Group.
Send Inquiry

Product Introduction

We supply you best benefit of money and we're ready to create with each other with filtering transformer oil, winding resistance test set, transformer oil filtering degassing and drying unit. Our company is willing to be honest with you, cooperate sincerely, and open the source of interests together. We insist on arming our employees with advanced ideas, improving their quality with various forms of training, and bringing their potential into play with scientific performance assessment. We achieve high quality and high efficiency management mode through scientific methods.

1. Introduction & Application

FTKZ-50A Transformer On-No Load Characteristics Analyzer is the latest product of FUOOTECH Group. This transformer on load loss tester adopts the popular ARM processor in this year, with 168M basic frequency and 128m memory, which can be expanded to 4G memory card. Using 7-inch high-definition color touch panel, combined with emwin display interface so as to make the instrument interface being friendly and operated in a simple way, it can be operated through the touchscreen without keyboard. The instrument support database and can be exported through USB disk or transmitted to computer via data wire.

 

The circuit design of this instrument is exquisite and unique, which makes it superior in performance, powerful in function, small in size and light in weight. It can not only be used to test the on-no load parameters of transformer, but also measure the harmonic content and waveform in the field. The instrument can record the test curve of transformer under on-no load condition, then provide reliable basis for transformer fault analysis.

Product details of transformer No load and load loss tester

2. Why On Site Transformer Empty Load Characteristics Tester Load Loss Test of transformer is required?

Energy source in the world especially in the developping and undevelopped countries is more and more short, air pollution is more and more serious, which forwards higher requirement on energy saving of the power transformer. Whenever a power transformer is energized , its core will consume energy and this energy will be in form of heat and it is called no-lead losses, these losses will be always present whether the transformer carries load or not.

Loss measurement of the transformer at low power factor always makes the whole industry confused for many years, therefore it is only solved through procurement from developped country at high price.

 

FUOOTECH developped this Transformer Empty Load Test Bed Power Analyzer under strong support of National Science and Technology Fund after difficult investigation for many years. This high technology product with own intelligent property not only reaches international advanced level for precision measurement at low power factor, its innovative data automatic locking technology is characterized with accurate locking, no artificial interference, which can improve working efficiency tens times.

 

The instrument applies 7.0 inch colourful liquid crystal display screen and the intelligent touching control technology, operation is more convenient.

 

Performance of the instrument is excellent, which is extensively applied in motor and air fan, power, and other industries.

Transformer Empty Load Characteristics Analyzer using at site

3. Technical Parameters

1) Voltage measurement scope: AC 10~1000V

2) Current measurement scope: AC 0.1 ~50 A

3) Measurement accuracy:

Voltage: 0.1%±0.005V (frequency 40~70Hz)

0.5%±0.005V (frequency 70~200Hz)

Current: 0.1%±0.0002A (frequency 40~70Hz)

0.5%±0.0002A (frequency 70~200Hz)

Power: P×0.1%± (U×I×0.02%) ±0.05W (P is power factor, U is reading of voltage effective value, I is reading of current effective value)
 

4) Working power supply: AC220V±10%, 50/60 Hz

5) Working temperature: -20℃~40℃

6) Relative humidity: ≤80%RH no dewing

7) Volume: 360×360×200mm

8) Weight: 12kg

 

4. Functions and Features

1). It can measure voltage, current, angle, power and other electrical parameters, and it also can display the vector diagram of voltage and current, both of the displays are shown clearly and intuitively on the same screen.
2). It can measure the parameters such as no-load loss, load loss and impedance voltage, etc.

3). The instrument has the function of harmonic analysis. It can measure the 1-32 harmonic content of voltage and current applied to transformer and display bar graph as well as voltage and current waveform.

 

4). The on-no characteristic curve under different voltage and current can be recorded automatically during the test process of on-no load condition of transformer, which can be more convenient to analyze the characteristics of transformer and core.
5). With the function of data storage and data browsing, the instrument supports DBF database, and it can store test data or browse test records according to user requirements. The instrument also supports the USB disk export function, you can export the test data through USB disk, and the database supports the excel spreadsheet opening mode, which is convenient for editing, printing or archiving.

6). Operate with 7-inch true color touch screen, the GUI interface, with build-in 128M memory (extensible 4G memory card), it supports English and is easy to operate.
7). It is small in size, light in weight, accurate in measurement, no power off calendar and clock function, so it can store test time at any time.

 

5. Stocks at office

empty load noload loss tester in stocks

6. Packing, Delivery, Shipping and Payment

deliver fuootech Transformer no-load load tester

 

7. Certificates

FUOOTECH empty load noload loss tester certificate

 

8. Packing List

No.

Item

Qty

1

Main engine

1

2

Power line

1

3

Ground lead

1

4

Touch Pen

1

5

Fuse pipe

2

6

Print paper

1

7

Voltage line

1

8

Current line

1

fuootech W.jpg

We manufacture Automatic Capacitance Dissipation Test 12kv Capacitance Tan Delta Tester Transformer Dielectric Loss Analysis to help customers succeed with pioneering spirit, excellent technology and innovation ability. We win customers with integrity and mutual benefit, forge ahead with innovation, expand the market, improve development, increase strength and embrace the future. With the high-quality, low-cost, large-scale and advanced positioning of domestically produced first-class products, we have taken a leading position in the field and represent a relatively high level in China.